{"product_id":"5shy55l4500-abb-asymmetric-igct","title":"5SHY55L4500 ABB asymmetric IGCT","description":"\u003cp\u003eConfigured for high-power medium-frequency power conversion in industrial drive networks, the \u003cstrong\u003eABB 5SHY55L4500\u003c\/strong\u003e (\u003cstrong\u003e5SHY55L4500\u003c\/strong\u003e Asymmetric IGCT Module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eModel Suffix\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eCore Function Architecture\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eArchitectural Application\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SHY55L4500\u003c\/td\u003e\n\u003ctd\u003eAsymmetric Integrated Gate-Commutated Thyristor Module\u003c\/td\u003e\n\u003ctd\u003eIndustrial Converters and Power Transmission\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5SHY...\u003c\/td\u003e\n\u003ctd\u003eBase Variant Family\u003c\/td\u003e\n\u003ctd\u003eABB High-Power Semiconductor Switching Interfaces\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e5SHY55L4500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSwitzerland\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.90 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e439.0 mm x 173.0 mm x 41.0 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +125 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eSnubberless turn-off power architecture\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating (VDRM)\u003c\/td\u003e\n\u003ctd\u003e4500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Rating (ITGQM)\u003c\/td\u003e\n\u003ctd\u003e5000 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Force\u003c\/td\u003e\n\u003ctd\u003e40 kN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity and Deterministic Switching Networks\u003c\/h3\u003e\n\u003cp\u003eThe 5SHY55L4500 module integrates a high snubberless turn-off rating and optimized medium-frequency response across deterministic power switching networks. It maintains precise control interface timing with status feedback and high backplane bus communication velocity compatibility to ensure synchronized execution in multi-module converter topologies. Furthermore, internal semiconductor design guarantees robust electromagnetic immunity and reliable asymmetric forward blocking up to 4500 V without requiring reverse voltage capability.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the maximum controllable turn-off current rating for the 5SHY55L4500 module?\u003c\/p\u003e\n\u003cp\u003eA: The module features a maximum controllable current rating (ITGQM) of 5000 A at a blocking voltage of 4500 V.\u003c\/p\u003e\n\u003cp\u003eQ: What mechanical mounting force is required to secure the module during installation?\u003c\/p\u003e\n\u003cp\u003eA: The device requires a specified mounting force of 40 kN to maintain proper thermal and electrical contact with heat sink surfaces.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eEnsure that all high-voltage power distribution feeds are completely de-energized, discharged, and locked out prior to handling the 5SHY55L4500 module. Apply thermal interface compound evenly across the contact surfaces and use a calibrated hydraulic clamping tool to exert the specified 40 kN mounting force uniformly across the semiconductor package. Verify that gate control leads and feedback interfaces are secured tightly before initiating low-voltage operational tests.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":45289334866035,"sku":"5SHY55L4500","price":233.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/QQ20260421-151624_32b4b56d-96ef-4c04-9952-9b2aa96f59cc.png?v=1785305909","url":"https:\/\/www.dcssupplier.com\/ar\/products\/5shy55l4500-abb-asymmetric-igct","provider":"DcsSupplier Limited","version":"1.0","type":"link"}