{"product_id":"aam10-s1-yokogawa-analog-input-module","title":"AAM10 S1 Yokogawa Analog Input Module","description":"\u003cp\u003eConfigured for high-precision signal acquisition in CENTUM CS series control platforms, the \u003cstrong\u003eYokogawa AAM10 S1\u003c\/strong\u003e (\u003cstrong\u003eAAM10-S1\u003c\/strong\u003e Analog Input Module) provides direct physical\/electrical execution of dual-channel current and voltage input conversion, galvanic signal decoupling, and field-to-controller data scaling.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eAAM10 S1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSystem dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.63 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e5.1 cm x 25.4 cm x 11.4 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eIndustrial ambient range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eSystem backplane dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Capacity\u003c\/td\u003e\n\u003ctd\u003e2 Independent Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eYokogawa DCS Process Control Characteristics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e4-20 mA HART loop protocol:\u003c\/strong\u003e The AAM10 S1 interfaces with process loops to acquire primary measurement variables. It maintains the necessary impedance to support HART-compliant field devices, allowing the DCS to extract secondary diagnostic data alongside the 4-20 mA analog signal.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFOUNDATION Fieldbus \/ Profibus PA connectivity:\u003c\/strong\u003e The module integrates into the CENTUM I\/O nest to provide physical signal conversion for legacy or digital-hybrid loops. This connectivity is mandatory to bridge field-side signal variations with the deterministic communication requirements of the CS series control bus.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel-to-channel isolation:\u003c\/strong\u003e The module features independent signal paths to decouple the two analog inputs. This is mandatory to prevent common-mode electrical noise or ground potential differences from interfering with the measurement accuracy of adjacent loops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCold junction compensation (CJC):\u003c\/strong\u003e The module is engineered for thermal stability within the I\/O nest. Its internal layout minimizes localized heating to ensure that reference values used for voltage signal conditioning remain consistent, preventing drift in measured process variables.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the AAM10 S1 input range be modified for non-standard signal voltages?\u003c\/p\u003e\n\u003cp\u003eA: No. The input range is defined by the hardware design to meet specific industrial signal standards. Any modification requires external signal conditioning or attenuators, as exceeding the module’s rated voltage\/current will result in permanent damage to the input stage.\u003c\/p\u003e\n\u003cp\u003eQ: Is this module capable of hot-swapping during active operation?\u003c\/p\u003e\n\u003cp\u003eA: Hot-swapping is restricted by the specific I\/O nest configuration. Always check the DCS system status and ensure the software has inhibited the corresponding I\/O points before removing or installing the module to prevent electrical faults and controller communication errors.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Install the module into the designated I\/O nest slot, ensuring full mechanical engagement with the backplane connector. Secure the module using the built-in locking mechanism, as firm seating is mandatory for maintaining electrical contact integrity.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Bond the I\/O nest frame to the cabinet’s primary safety ground bus using low-impedance conductors. A clean ground connection is mandatory to ensure the efficacy of the 1500 V isolation barrier and to shield analog signals from external EMI.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Terminate analog inputs using high-quality shielded, twisted-pair cabling. Maintain a minimum of 150 mm separation from high-voltage AC conduits to prevent inductive coupling, which is mandatory to maintain the measurement accuracy of the 4-20 mA signals.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":45188873257075,"sku":"AAM10 S1","price":233.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/screenshot_2026-07-08_15-30-27.png?v=1783500270","url":"https:\/\/www.dcssupplier.com\/ar\/products\/aam10-s1-yokogawa-analog-input-module","provider":"DcsSupplier Limited","version":"1.0","type":"link"}