{"product_id":"abb-1vcf014629r802-vacuum-circuit-breaker-component","title":"ABB 1VCF014629R802 Vacuum Circuit Breaker Component","description":"\u003cp\u003eThe \u003cstrong\u003eABB 1VCF014629R802\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e1VCF014629R802\u003c\/strong\u003e Vacuum Circuit Breaker Component, operates as a dedicated hardware component for mechanical actuation and arc interruption execution within ABB medium-voltage vacuum circuit breakers.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1VCF014629R802\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eCommercial Data Not Specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003ePhysical Weight Not Specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003ePhysical Dimensions Not Specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eStandard Industrial Operating Range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eSubstation Bus \/ Actuator Powered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication Class\u003c\/td\u003e\n\u003ctd\u003eMedium-Voltage Switchgear Subassemblies\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBreaker Type\u003c\/td\u003e\n\u003ctd\u003eVacuum Circuit Breaker (VCB) Platforms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003eInternal Switchgear Chassis Assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDynamic Loop Response and Firmware Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe circuit breaker subassembly interfaces directly with internal trip mechanisms and auxiliary signaling circuits, translating trip coil commands into physical contact separation. Dynamic mechanical linkage geometry provides high-speed actuator loop feedback response during fault interlock sequences, suppressing electrical arc duration. Precision dimensional tolerances maintain mechanical firmware flash compatibility with upstream protection relays and automated breaker racking mechanisms, preventing interlock failure during high-stress trip operations.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What primary role does the 1VCF014629R802 play within medium-voltage switchgear?\u003c\/p\u003e\n\u003cp\u003eA: The part functions as an internal OEM replacement component, executing physical arc interruption and contact separation inside ABB vacuum circuit breaker assemblies.\u003c\/p\u003e\n\u003cp\u003eQ: Are mechanical modifications required to install this part into compatible ABB breakers?\u003c\/p\u003e\n\u003cp\u003eA: No, the component is manufactured as a drop-in OEM assembly designed to match factory mounting tolerances without mechanical adaptation.\u003c\/p\u003e\n\u003cp\u003eQ: How does the component handle repeated mechanical trip cycles?\u003c\/p\u003e\n\u003cp\u003eA: Built with industrial-grade materials, the part withstands thermal stress and mechanical shock during high-current fault interruption and routine switching cycles.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eLock out and tag out all primary medium-voltage feeds and auxiliary control power supplies before racking out the vacuum circuit breaker.\u003c\/li\u003e\n\u003cli\u003eDischarge stored energy springs within the breaker mechanism according to ABB safety procedures prior to removing structural covers.\u003c\/li\u003e\n\u003cli\u003eReplace the worn component, torquing all internal mechanical fasteners to ABB specified force limits to ensure proper contact alignment.\u003c\/li\u003e\n\u003cli\u003ePerform manual charge, close, and trip operational tests to verify smooth mechanical travel before racking the breaker back into the live switchgear cubicle.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":45394288345203,"sku":"1VCF014629R802","price":233.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/1VCF014629R802_1200x1200_cee26cd0-6427-4071-8280-44ba7c99058f.png?v=1787562020","url":"https:\/\/www.dcssupplier.com\/ar\/products\/abb-1vcf014629r802-vacuum-circuit-breaker-component","provider":"DcsSupplier Limited","version":"1.0","type":"link"}