{"product_id":"abb-5shx0660f0002-3bhb018104r0001-reverse-conducting-igct-module","title":"ABB 5SHX0660F0002 3BHB018104R0001 Reverse-Conducting IGCT Module","description":"\u003cp\u003eThe \u003cstrong\u003eABB 3BHB018104R0001\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e5SHX0660F0002\u003c\/strong\u003e IGCT Module, operates as a dedicated hardware component for power semiconductor switching within ACS5000 medium-voltage drive systems.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e3BHB018104R0001 (5SHX0660F0002)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eStandard ABB Factory Specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.5 to 2.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e51 mm \/ 68 mm Wafer Press-Pack Housing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +125 deg C Junction Temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eLow Conduction Loss Switching Assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlocking Voltage\u003c\/td\u003e\n\u003ctd\u003e3300 V (V_DRM \/ V_RRM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTurn-off Current\u003c\/td\u003e\n\u003ctd\u003eUp to 660 A (I_TGQM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOn-State Voltage\u003c\/td\u003e\n\u003ctd\u003e2.0 to 2.5 V at Nominal Current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003edv\/dt Immunity\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 2000 V\/us\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003edi\/dt Capability\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 1000 A\/us\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRequired Clamping Force\u003c\/td\u003e\n\u003ctd\u003e8 to 12 kN Axial Force\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Method\u003c\/td\u003e\n\u003ctd\u003eForced Air or Liquid Heatsink\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity and Deterministic Networks\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe ABB 3BHB018104R0001 interfaces directly with external gate units, maintaining communication velocity across fiber-optic control links.\u003c\/li\u003e\n\u003cli\u003eReverse-conducting IGCT architecture integrates the freewheeling diode, optimizing physical I\/O density scaling and stack integration in inverter legs.\u003c\/li\u003e\n\u003cli\u003eSeamless firmware flash compatibility across drive controllers is preserved as control logic and parameters reside within the primary CPU unit.\u003c\/li\u003e\n\u003cli\u003eHigh dv\/dt (\u0026gt; 2000 V\/us) and di\/dt (\u0026gt; 1000 A\/us) ratings ensure fast, deterministic switching performance in 2.3 to 4.16 kV drive topologies.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the 3BHB018104R0001 IGCT module support live removal or hot-swapping?\u003c\/p\u003e\n\u003cp\u003eA: No, live removal is strictly prohibited; total power isolation and complete DC link capacitor discharge (verify \u0026lt; 50 V) are mandatory prior to servicing.\u003c\/p\u003e\n\u003cp\u003eQ: Is drive control software reprogramming required after installing a replacement 3BHB018104R0001 module?\u003c\/p\u003e\n\u003cp\u003eA: No, control parameters reside within the drive controller; however, gate unit driver firmware compatibility should be verified.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eEnsure main supply and control power are fully disconnected and locked out before installation. Discharge DC link capacitors for at least 5 minutes and verify zero voltage using a multimeter on the bus bars. Wear an ESD wrist strap and clean the module contact surfaces with isopropyl alcohol. Apply a thin layer of thermal compound to the press-pack housing if specified. Align the module inside the stack assembly and tighten the clamping fixture evenly in a cross pattern to apply an axial force of 8 to 12 kN using a calibrated tool. Reconnect fiber-optic gate channels and perform an insulation resistance measurement (\u0026gt; 100 Mohm at 500 VDC) prior to re-energizing the drive.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":45320219983987,"sku":"5SHX0660F0002 3BHB018104R0001","price":233.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/QQ20260421-161618_c202c1d7-52d3-4d8b-8b1e-906e962060ca.png?v=1786000721","url":"https:\/\/www.dcssupplier.com\/ar\/products\/abb-5shx0660f0002-3bhb018104r0001-reverse-conducting-igct-module","provider":"DcsSupplier Limited","version":"1.0","type":"link"}