{"product_id":"abb-ai561-1tne968902r1101-analog-input-module","title":"ABB AI561 1TNE968902R1101 Analog Input Module","description":"\u003cp\u003eThe \u003cstrong\u003eABB AI561\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eAI561\u003c\/strong\u003e (1TNE968902R1101) Analog Input Module, operates as a dedicated hardware component for 4-channel voltage and current signal acquisition within S500-eCo distributed automation networks.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eModel Suffix\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eCore Function Architecture\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eArchitectural Application\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAI561 \/ 1TNE968902R1101\u003c\/td\u003e\n\u003ctd\u003eS500-eCo Analog Input Module (4 AI: U, I)\u003c\/td\u003e\n\u003ctd\u003eABB S500-eCo Distributed I\/O Systems\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAI500-...\u003c\/td\u003e\n\u003ctd\u003eBase Variant Family\u003c\/td\u003e\n\u003ctd\u003eABB S500 Analog Input Interface Assemblies\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eAI561 (1TNE968902R1101)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eGermany \/ Global Manufacturing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.12 kg (0.16 kg gross)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e34.0 mm x 74.0 mm x 135.0 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eInternal bus and external 24 V DC loop supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e4 configurable channels (Voltage, Current)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e12-bit analog input conversion\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDegree of Protection\u003c\/td\u003e\n\u003ctd\u003eIP20 housing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProfinet \/ EtherNet\/IP Deterministic Networks and Driver Integration\u003c\/h3\u003e\n\u003cp\u003eThe module incorporates 4 pluggable analog input channels supporting voltage and current signals across deterministic control loops. It maintains high backplane bus communication velocity compatibility and precise conversion timing to ensure synchronized execution in S500-eCo distributed I\/O topologies. Furthermore, internal signal conditioning circuitry guarantees robust electromagnetic immunity, firmware flash compatibility, and reliable channel isolation under high I\/O density scaling demands.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How many analog input channels are available on the AI561 module?\u003c\/p\u003e\n\u003cp\u003eA: The module features 4 analog input channels supporting voltage (U) and current (I) signal types.\u003c\/p\u003e\n\u003cp\u003eQ: What is the conversion resolution of the analog inputs on this S500-eCo module?\u003c\/p\u003e\n\u003cp\u003eA: The inputs provide a conversion resolution of 12 bits for process measurement processing.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eEnsure that all system power distribution and external supply rails are completely de-energized and locked out prior to mounting or wiring the AI561 module. Secure the unit onto a standard DIN rail, ensuring proper mechanical and electrical engagement with the terminal base. Route signal wiring through shielded twisted-pair cables, terminating the shield ground appropriately to prevent noise interference, and verify correct signal polarity before restoring power.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":45289345712243,"sku":"AI561 1TNE968902R1101","price":233.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/screenshot_2026-05-15_17-43-10_4e863acd-cc4d-425e-abb9-ee68f35c0a57.png?v=1785305341","url":"https:\/\/www.dcssupplier.com\/ar\/products\/abb-ai561-1tne968902r1101-analog-input-module","provider":"DcsSupplier Limited","version":"1.0","type":"link"}