{"product_id":"abb-ci511-ethcat-1sap220900r0001-s500","title":"ABB CI511-ETHCAT 1SAP220900R0001 S500","description":"\u003cp\u003eConfigured for EtherCAT slave communication and mixed analog\/digital signal processing in distributed control architectures, the \u003cstrong\u003eABB CI511-ETHCAT (1SAP220900R0001)\u003c\/strong\u003e (\u003cstrong\u003eCI511-ETHCAT\u003c\/strong\u003e) interface module provides direct physical and electrical execution of network telegram routing and process I\/O data exchange.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eCI511-ETHCAT\u003c\/strong\u003e: Base designation for the ABB S500 modular EtherCAT communication and distributed I\/O interface platform.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1SAP220900R0001\u003c\/strong\u003e: Unique ordering part identifier cataloging the hardware build, integrated mixed analog\/digital I\/O complement, and factory default firmware parameters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCI511-ETHCAT 1SAP220900R0001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBrand\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOrigin\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.138 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e67.5 mm x 62 mm x 76 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temp\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMax 5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20.4 to 28.8 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalog Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 channels (Voltage, Current, RTD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAnalog Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 channels (Voltage, Current)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigital Inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 channels (24 V DC, 5 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDigital Outputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8 channels (24 V DC, 0.5 A transistor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eSystem Integration and Control Architecture\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Bus Communication Velocity\u003c\/strong\u003e: Executes deterministic internal data routing across high-speed S500 bus interfaces to support expansion of up to 10 local I\/O extension modules.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProfinet \/ EtherNet\/IP Deterministic Networks\u003c\/strong\u003e: Implements high-speed EtherCAT slave protocols over dual industrial Ethernet interfaces to maintain predictable telegram update intervals in distributed topologies.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/O Density Scaling\u003c\/strong\u003e: Manages a fixed complement of analog channels (voltage, current, RTD) and digital channels alongside built-in cam switch functionality without modifying base rack architecture.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFirmware Flash Compatibility\u003c\/strong\u003e: Permits non-volatile software parameter updates and configuration modifications via system-level engineering software tools.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the CI511-ETHCAT module be replaced while the system rack is energized?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No, module replacement requires isolating the 24 V DC auxiliary supply to prevent internal bus corruption and terminal short-circuits.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How many additional I\/O modules can be connected to this interface unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The module supports expansion by up to 10 discrete I\/O modules via the internal S500 expansion bus.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What types of analog sensors are supported by the analog input channels?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The 4 analog input channels natively support voltage (U), current (I), and resistance temperature detector (RTD) measurements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the module securely onto a standard DIN rail, ensuring proper locking latch engagement for mechanical stability against operational vibration.\u003c\/li\u003e\n\u003cli\u003eConnect the 24 V DC supply voltage to the designated terminal blocks, verifying correct polarity before energizing the unit.\u003c\/li\u003e\n\u003cli\u003eTerminate shield drain wires from field analog and digital signal cables to the nearest functional earth ground bar to reduce electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003eMaintain adequate spacing above and below the IP20-rated enclosure to facilitate natural thermal convection across the specified operating temperature range.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":45286396330099,"sku":"CI511-ETHCAT 1SAP220900R0001","price":233.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/screenshot_2026-07-28_09-50-42_c40e7a11-3244-476f-b604-463942b35b9e.png?v=1785203777","url":"https:\/\/www.dcssupplier.com\/ar\/products\/abb-ci511-ethcat-1sap220900r0001-s500","provider":"DcsSupplier Limited","version":"1.0","type":"link"}