{"product_id":"abb-ntmu01-termination-mounting-unit","title":"ABB NTMU01 Termination Mounting Unit","description":"\u003cp\u003eThe \u003cstrong\u003eABB NTMU01\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eNTMU01\u003c\/strong\u003e Termination Mounting Unit, serves as the primary \u003cstrong\u003eNTMU01\u003c\/strong\u003e physical mounting and interface chassis utilized to execute termination card placement and signal routing paths across ABB Bailey Net 90 and Infi 90 distributed control system platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel \/ Part Number\u003c\/td\u003e\n\u003ctd\u003eNTMU01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB (Bailey)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eStandard multi-slot passive baseplate weight profile\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eMulti-position structural rack-mount configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eStandard industrial control cabinet environmental baseline\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive electrical bus distribution topology (Zero active power draw)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eBAINET Termination Mounting Unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCustoms Tariff Number\u003c\/td\u003e\n\u003ctd\u003e8537109150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Order Quantity\u003c\/td\u003e\n\u003ctd\u003e1 EA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Control and Drive Architecture\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Bus Communication Velocity\u003c\/strong\u003e The mounting unit provides the passive internal backplane trace layout necessary to route signals directly between terminal blocks and the host control processor. This direct connection preserves bus transmission velocity by eliminating active conversion components or software-driven handling latencies.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProfinet \/ EtherNet\/IP Deterministic Networks\u003c\/strong\u003e The hardware layout acts as a physical isolation barrier that organizes structural multi-cable interfaces. It prevents electrical cross-talk and impedance mismatches at the termination boundary, helping protect deterministic network communication cycles on primary controller segments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/O Density Scaling and Physical Termination\u003c\/strong\u003e Designed to support multiple multi-channel termination modules, the hardware optimizes slot density limits within standard marshalling cabinets. It organizes clustered field lines into structured terminal bays, allowing high-density signal distribution without structural binding or thermal crowding.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the primary difference between the NTMU01 and standard terminal blocks?\u003c\/p\u003e\n\u003cp\u003eA: The NTMU01 is a multi-slot backplane-style frame that accepts dedicated plug-in termination modules, bridging heavy-gauge field wiring directly to the high-density internal bus cables of the control system via structured connection paths rather than simple point-to-point terminals.\u003c\/p\u003e\n\u003cp\u003eQ: Does the NTMU01 backplane distribute auxiliary field power to installed termination cards?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The passive internal bus structure includes dedicated copper power plane layers designed to route system-wide auxiliary VDC supplies to individual termination modules, eliminating the need to daisy-chain external power lines to every single slot.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":45089276919923,"sku":"NTMU01","price":233.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/screenshot_2026-06-10_17-25-42_28293530-33b1-4a63-8461-4e893ed5deac.png?v=1781085284","url":"https:\/\/www.dcssupplier.com\/ar\/products\/abb-ntmu01-termination-mounting-unit","provider":"DcsSupplier Limited","version":"1.0","type":"link"}