{"product_id":"abb-pharpspep21013-6644463a2-power-entry-panel","title":"ABB PHARPSPEP21013 6644463A2 Power Entry Panel","description":"\u003cp\u003eThe \u003cstrong\u003eABB PHARPSPEP21013\u003c\/strong\u003e, also cataloged under part number \u003cstrong\u003e6644463A2\u003c\/strong\u003e MPS III Power Entry Panel, operates as a dedicated hardware component for localized routing, electrical distribution, and main line conditioning within Symphony Plus \/ INFI 90 automated control systems. The dual-chassis hardware manages incoming electrical feeds under strict Category III application standards, dividing load capacity cleanly while enforcing physical power separation across parallel control tracks.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003ePHARPSPEP21013 (6644463A2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType Designation\u003c\/td\u003e\n\u003ctd\u003eMPS III\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e8.709 kg (19.20 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e220 mm width x 540 mm depth x 180 mm height\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003ePower Entry Panels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication Scope\u003c\/td\u003e\n\u003ctd\u003eDual-chassis Category III infrastructure power distribution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Complement\u003c\/td\u003e\n\u003ctd\u003e0 internal batteries integrated into the structural panel frame\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCustoms Tariff \/ HS Code\u003c\/td\u003e\n\u003ctd\u003e853710911 \/ 853710\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Control \u0026amp; Driving Subsystem Routing\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/O Density Scaling and Process Terminal Interconnection\u003c\/strong\u003e The dual-chassis power entry panel structures incoming baseline electricity into multiple segregated distribution outputs. By splitting line power across two independent internal chassis networks, the module provides a safe physical layout to scale high-density automation arrays, preventing a localized electrical short or circuit fault from interrupting parallel processing operations across the master panel architecture.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Bus Communication Velocity Licences and Firmware Flash Compatibility\u003c\/strong\u003e This panel functions as a high-density, electromechanical power tier underlying active communication buses. Because it operates strictly on physical circuit distribution tracks, circuit breakers, and filter components, it operates with zero code execution delay. The device remains completely independent of software licences, system velocity updates, or live firmware flash compatibility checks.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the primary purpose of the dual-chassis configuration inside the PHARPSPEP21013 panel?\u003c\/p\u003e\n\u003cp\u003eA: The configuration divides internal electrical rails into two completely separate structural sections. This allows field engineers to run dual redundant power feeds through a single panel envelope or cleanly separate critical logic processing power from field instrumentation output loops.\u003c\/p\u003e\n\u003cp\u003eQ: What does the Category III application designation signify regarding standard electrical safety?\u003c\/p\u003e\n\u003cp\u003eA: Category III validation indicates that the hardware is built and tested to withstand high transient overvoltage surges typical of fixed electrical distribution installations. This includes primary sub-panel loops, industrial switchgear buses, and heavy-duty load feeder pathways directly connected to plant infrastructure.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":45094988906611,"sku":"PHARPSPEP21013 6644463A2","price":233.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/screenshot_2026-06-12_15-24-56_4428cba6-0f60-4e11-9504-dbf6436f75d4.png?v=1781251987","url":"https:\/\/www.dcssupplier.com\/ar\/products\/abb-pharpspep21013-6644463a2-power-entry-panel","provider":"DcsSupplier Limited","version":"1.0","type":"link"}