{"product_id":"abb-sf810int-los-uvir-t-l-flame-analysis-module","title":"ABB SF810INT-LOS-UVIR-T-L Flame Analysis Module","description":"\u003cp\u003eThe \u003cstrong\u003eABB SF810INT-LOS-UVIR-T-L\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eSF810INT-LOS-UVIR-T-L\u003c\/strong\u003e Flame Analysis Module, operates as a dedicated hardware component for multi-spectrum optical radiation monitoring within industrial burner control and combustion safety networks. The board-level sub-assembly conditions and processes combined ultraviolet (UV) and infrared (IR) sensor inputs natively at the hardware tier to verify real-time flame presence variables.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSF810INT-LOS-UVIR-T-L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSweden \/ Germany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage Gross Weight\u003c\/td\u003e\n\u003ctd\u003e1.3 kg total shipping mass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Net Dimensions\u003c\/td\u003e\n\u003ctd\u003e257 mm x 138 mm x 175 mm (Depth x Height x Width)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCustoms Tariff \/ HS Code\u003c\/td\u003e\n\u003ctd\u003e9027500000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Order Quantity\u003c\/td\u003e\n\u003ctd\u003e1 EA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpectral Evaluation Matrix\u003c\/td\u003e\n\u003ctd\u003eDual UV (Ultraviolet) and IR (Infrared) sensing tracks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Ingress Level\u003c\/td\u003e\n\u003ctd\u003eField-mountable transmitter geometry matching standard housings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInvoice Designation Tracking\u003c\/td\u003e\n\u003ctd\u003eCross-referenced against line item SF810INT-LOS-UV-T-C-W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWEEE Classification\u003c\/td\u003e\n\u003ctd\u003eSmall Equipment (no external dimension exceeding 50 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eFlame Analysis Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Control \u0026amp; Drives Backplane Infrastructure\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/O Density Scaling and Real-Time Signal Parsing\u003c\/strong\u003e The internal processor geometry samples dual-band radiation frequencies directly from field optical sensors, expanding analytical capabilities without demanding external multiplexing hardware. This design scales local system density by mapping critical flame status flags directly into host processing registers over active system buses.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eProfinet \/ EtherNet\/IP Deterministic Networks Coexistence\u003c\/strong\u003e The passive and active communication circuits isolate sensitive low-amplitude sensor signal lines from high-frequency system bus routing paths. This topology allows the module to pass continuous diagnostics to controllers running over Profinet \/ EtherNet\/IP deterministic networks without introducing tracking anomalies, transmission frame drops, or data packet errors.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How does the dual UV\/IR configuration handle background radiation discrimination?\u003c\/p\u003e\n\u003cp\u003eA: The module's internal logic runs simultaneous validation algorithms that cross-reference ultraviolet flicker frequencies with infrared amplitude changes. This hardware-tier discrimination allows the device to separate actual flame combustion signatures from background boiler refractory glow, preventing false-positive flame presence indications.\u003c\/p\u003e\n\u003cp\u003eQ: Does this analysis module require external power distribution modules for sensor loop excitation?\u003c\/p\u003e\n\u003cp\u003eA: No, the module conditions power directly from the host rack backplane bus, regulating it to deliver stabilized low-voltage excitation lines directly to the external optical sensors through the field termination pins.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":45109514109043,"sku":"SF810INT-LOS-UVIR-T-L","price":233.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/38_692304af-7f5d-4d49-bd2d-d247309fc063.png?v=1781664065","url":"https:\/\/www.dcssupplier.com\/ar\/products\/abb-sf810int-los-uvir-t-l-flame-analysis-module","provider":"DcsSupplier Limited","version":"1.0","type":"link"}