{"product_id":"abb-tc514v2-communication-module","title":"ABB TC514V2 Communication Module","description":"\u003cp\u003eThe \u003cstrong\u003eABB TC514V2\u003c\/strong\u003e, also cataloged under article number \u003cstrong\u003e3BSE013281R1\u003c\/strong\u003e Communication Module, operates as a dedicated hardware component for physical layer conversion, real-time signal repeating, and electrical-optical network interfacing within Advant Fieldbus 100 (AF100) control networks. The hardware provides bidirectional transmission matching between copper balanced lines and optical fiber mediums, enabling extended bus routing across the Advant Master Process Control System without data frame latency.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTC514V2 (3BSE013281R1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDesignation Type\u003c\/td\u003e\n\u003ctd\u003eAF100 Twisted pair\/opto modem (Optical fiber repeater)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSweden\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e0.34 kg (0.75 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e58 mm width x 168 mm depth x 122 mm height\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC nominal loop infrastructure requirement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Isolation\u003c\/td\u003e\n\u003ctd\u003e50 V structural dielectric boundary limit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eCommunication Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNetwork Interface\u003c\/td\u003e\n\u003ctd\u003eAdvant Fieldbus 100 (AF100) physical infrastructure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMedium Conversion\u003c\/td\u003e\n\u003ctd\u003eTwin-conductor shielded twisted-pair copper to optical fiber media\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Complement\u003c\/td\u003e\n\u003ctd\u003e0 internal batteries integrated within the enclosure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRegulatory Status\u003c\/td\u003e\n\u003ctd\u003eExempt from 2011\/65\/EU (RoHS) scope per Article 2(4) framework\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Control \u0026amp; Driving Subsystem Routing\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProfinet \/ EtherNet\/IP Deterministic Networks and I\/O Density Scaling\u003c\/strong\u003e The modem module acts as a transparent physical-layer transceiver interface within high-speed AF100 deterministic industrial networks. It directly translates differential electrical voltage transitions from copper media into high-frequency optical light pulses, allowing field-level data lines and distributed I\/O clusters to extend their physical communication limits across high-density plant topologies without degradation or data frame timing skew.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Bus Communication Velocity Licences and Firmware Flash Compatibility\u003c\/strong\u003e This optical repeater executes media conversion transitions entirely within its solid-state hardware transceiver arrays, resulting in zero software processing delay. Because it operates at the physical network layer without active microcontrollers or logic operating systems, it introduces no firmware flash dependencies or software licensing overhead, preserving the raw backplane bus communication velocities.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the primary operational distinction between standard copper AF100 routing and the TC514V2 optical link?\u003c\/p\u003e\n\u003cp\u003eA: Standard twisted-pair copper lines are susceptible to industrial electromagnetic interference (EMI) and have distance limitations. The TC514V2 repeating architecture bridges these gaps by converting standard electrical transmission streams into light waves, providing total galvanic isolation and enabling long-distance data loops through high-noise switchgear areas.\u003c\/p\u003e\n\u003cp\u003eQ: Does the TC514V2 transceiver require software driver configuration within the Advant Master environment?\u003c\/p\u003e\n\u003cp\u003eA: No. The media repeater operates completely as a hardware-defined transceiver unit. It processes the incoming physical wave signals directly, adapting instantly to existing bus lines without firmware flashing, device address mapping, or parameter initialization inside the system configuration software.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":45094989267059,"sku":"TC514V2","price":233.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/screenshot_2026-06-12_15-30-40_3119cef8-d013-4eb1-a734-ab2dede855a0.png?v=1781252377","url":"https:\/\/www.dcssupplier.com\/ar\/products\/abb-tc514v2-communication-module","provider":"DcsSupplier Limited","version":"1.0","type":"link"}