{"product_id":"allen-bradley-1734-oe2v-point-i-o-2-channel-analog-voltage-output-module","title":"Allen-Bradley 1734-OE2V POINT I\/O 2-Channel Analog Voltage Output Module","description":"\u003cp\u003eConfigured for high-density analog voltage signal generation in Allen-Bradley ControlLogix and CompactLogix platforms, the \u003cstrong\u003eAllen-Bradley 1734-OE2V\u003c\/strong\u003e (\u003cstrong\u003e1734-OE2V\u003c\/strong\u003e POINT I\/O 2-Channel Analog Voltage Output Module) provides direct physical\/electrical execution. The module converts 14-bit digital value registers from the controller backplane into 2 single-ended 0 to 10 VDC analog control signals for driving field actuators and speed reference inputs.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eThe catalog number \u003cstrong\u003e1734-OE2V\u003c\/strong\u003e follows standard Allen-Bradley POINT I\/O module naming conventions:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e1734\u003c\/strong\u003e: Identifies the compact modular POINT I\/O hardware system family.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOE\u003c\/strong\u003e: Designates an Analog Output Module (Output Expansion).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2\u003c\/strong\u003e: Specifies a 2-channel output density configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eV\u003c\/strong\u003e: Indicates 0 to 10 VDC voltage output signal mode.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1734-OE2V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.09 lbs (0.04 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard POINT I\/O Terminal Base Footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e1.0 W (Nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e2 Single-Ended Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e0 to 10 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Resolution\u003c\/td\u003e\n\u003ctd\u003e14 Bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Isolation\u003c\/td\u003e\n\u003ctd\u003eNon-Isolated (No channel-to-channel isolation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Format\u003c\/td\u003e\n\u003ctd\u003eDIN Rail Mountable (Open Style)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Control \u0026amp; Backplane Communication Properties\u003c\/h3\u003e\n\u003cp\u003eAs a core analog processing unit within Allen-Bradley distributed control structures, the 1734-OE2V features low-latency bus interaction and precise output signal scaling:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Bus Communication Velocity:\u003c\/strong\u003e High-speed POINTBus backplane connections transfer 14-bit digital output data frames continuously from the network adapter module with sub-millisecond updates across deterministic EtherNet\/IP networks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/O Density Scaling:\u003c\/strong\u003e Packs 2 high-resolution voltage output channels into an ultra-slim 12 mm module width, maximizing rack space efficiency while maintaining hardware-level D\/A conversion precision.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFirmware Flash Compatibility:\u003c\/strong\u003e Supports seamless hardware execution across dynamic controller firmware flashing events, preserving output scaling configurations and fault-state hold settings stored in non-volatile memory.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Are the analog output channels on the 1734-OE2V isolated from each other?\u003c\/p\u003e\n\u003cp\u003eA: No, the 1734-OE2V features single-ended non-isolated output channels that share a common negative reference return line.\u003c\/p\u003e\n\u003cp\u003eQ: What mounting base hardware is required to install the module on a standard DIN rail?\u003c\/p\u003e\n\u003cp\u003eA: The module snaps directly into a standard 1734-TB or 1734-TBS POINT I\/O terminal base assembly mounted on a 35 mm DIN rail.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eStrict adherence to proper mechanical assembly and wiring practices ensures stable D\/A conversion accuracy in noisy electrical environments:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Mounting and Terminal Base Assembly:\u003c\/strong\u003e Snap the 1734 terminal base securely onto the 35 mm DIN rail before inserting the 1734-OE2V module. Ensure the mechanical keying dial on the base is rotated to the correct position for analog output modules prior to seating.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring and Signal Shielding:\u003c\/strong\u003e Connect analog voltage output devices using two-conductor twisted-pair shielded cable. Connect the cable shield to the cabinet single-point ground bus bar; do not ground shields at the field device to prevent ground loop noise from shifting signal accuracy.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Separation:\u003c\/strong\u003e Route low-voltage 0 to 10 VDC analog output lines in dedicated wireways separate from 120\/240 VAC power lines and variable frequency drive motor cables to prevent electromagnetic noise induction.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":45303560011891,"sku":"1734-0EV2","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/screenshot_2026-08-04_14-31-53_9c461ff1-1116-47e4-86ff-2c080a6b2eb5.png?v=1785825977","url":"https:\/\/www.dcssupplier.com\/ar\/products\/allen-bradley-1734-oe2v-point-i-o-2-channel-analog-voltage-output-module","provider":"DcsSupplier Limited","version":"1.0","type":"link"}