{"product_id":"allen-bradley-1746-oap12-slc-500-12-pt-ac-output-module","title":"Allen Bradley 1746-OAP12 SLC 500 12-Pt AC Output Module","description":"\u003cp\u003eThe Allen Bradley \u003cstrong\u003e1746-OAP12\u003c\/strong\u003e is a 12-point digital AC output module for SLC 500 chassis installations, designed for higher-current 120 \/ 240 VAC switching loads. It divides its 12 outputs into two isolated groups of 6 points per common, uses a Removable Terminal Block (RTB), and supports configurable blown-fuse CPU fault monitoring.\u003c\/p\u003e\n\u003ch2\u003eTechnical Specifications\u003c\/h2\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1746-OAP12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Line\u003c\/td\u003e\n\u003ctd\u003eSLC 500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eDigital AC Output Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Outputs\u003c\/td\u003e\n\u003ctd\u003e12 (6 points per common)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Output Voltage\u003c\/td\u003e\n\u003ctd\u003e120 \/ 240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage Range\u003c\/td\u003e\n\u003ctd\u003e85 - 265 VAC, 47 - 63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous Current per Point\u003c\/td\u003e\n\u003ctd\u003e2.0 A at 30 deg C (86 deg F), 1.25 A at 55 deg C (131 deg F), 1.0 A at 60 deg C (140 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous Current per Module (Max)\u003c\/td\u003e\n\u003ctd\u003e9.0 A at 30 deg C (86 deg F), 6.8 A at 55 deg C (131 deg F), 6.0 A at 60 deg C (140 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Load Current per Point\u003c\/td\u003e\n\u003ctd\u003e10 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSurge Current\u003c\/td\u003e\n\u003ctd\u003e17 A for 25 ms per point (repeatable every 2 s at 60 deg C); 35 A per common for 10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOFF-State Leakage Current (Max)\u003c\/td\u003e\n\u003ctd\u003e2 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Delay Time (OFF to ON)\u003c\/td\u003e\n\u003ctd\u003e11 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Delay Time (ON to OFF)\u003c\/td\u003e\n\u003ctd\u003e1 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Drop at 2.0 A\u003c\/td\u003e\n\u003ctd\u003e1.2 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Current at 5 VDC\u003c\/td\u003e\n\u003ctd\u003e370 mA (0.370 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Current at 24 VDC\u003c\/td\u003e\n\u003ctd\u003e0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Heat Dissipation (Max)\u003c\/td\u003e\n\u003ctd\u003e10.85 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 - 60 deg C (32 - 140 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5 - 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperational Shock\u003c\/td\u003e\n\u003ctd\u003e30 G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration\u003c\/td\u003e\n\u003ctd\u003e5 G at 10 - 500 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.44 lbs (0.65 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUPC\u003c\/td\u003e\n\u003ctd\u003e662468434140\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch2\u003eGroup Isolation and Current Derating\u003c\/h2\u003e\n\u003cp\u003eEach 6-point output group is isolated from the other group, allowing loads on one common group to continue operating if the fuse on the other group opens. Because output current ratings derate with ambient temperature, verify load totals against both per-point and per-module limits at the highest expected chassis temperature.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eA minimum load current of 10 mA per point is required for proper output operation.\u003c\/li\u003e\n\u003cli\u003eMaximum OFF-state leakage current is 2 mA per point, which should be considered with sensitive AC loads.\u003c\/li\u003e\n\u003cli\u003eVoltage drop reaches 1.2 VDC at 2.0 A, and total module heat dissipation reaches up to 10.85 W.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFuse Monitoring and Processor Behavior\u003c\/h2\u003e\n\u003cp\u003eThe module includes a jumper to select whether a blown fuse triggers a processor fault. By default, the jumper shorts pins 2 and 1 with fuse monitoring disabled; moving the jumper to short pins 2 and 3 enables blown-fuse monitoring.\u003c\/p\u003e\n\u003cp\u003eWhen used with SLC 5\/02 and later processors, programming a fault routine is not compatible for clearing the major fault bit. The major fault bit is S:1\/13 with the major fault code recorded in S:6.\u003c\/p\u003e\n\u003ch2\u003eReplacement Fuse Kit\u003c\/h2\u003e\n\u003cp\u003eWhen a fuse blows, replace it with a \u003cstrong\u003eSAN-O HQ 6.3A\u003c\/strong\u003e fuse to maintain UL\/CSA ratings. The matching replacement fuse kit is catalog number \u003cstrong\u003e1746-F9\u003c\/strong\u003e, which contains 5 fuses per kit.\u003c\/p\u003e\n\u003ch2\u003eFrequently Asked Questions\u003c\/h2\u003e\n\u003cp\u003eQ: How do I enable blown-fuse monitoring on the \u003cstrong\u003e1746-OAP12\u003c\/strong\u003e? A: Set the internal monitoring jumper to short pins 2 and 3. By default, the jumper is positioned across pins 2 and 1, which leaves fuse monitoring disabled.\u003c\/p\u003e\n\u003cp\u003eQ: Can I use a fault routine on SLC 5\/02 and later processors to clear the major fault bit for this module? A: No. With SLC 5\/02 and later processors, programming a fault routine is not compatible for clearing the major fault bit (S:1\/13, with the major fault code stored in S:6).\u003c\/p\u003e\n\u003cp\u003eQ: What replacement fuse and kit apply to the \u003cstrong\u003e1746-OAP12\u003c\/strong\u003e? A: Use a \u003cstrong\u003eSAN-O HQ 6.3A\u003c\/strong\u003e fuse to maintain UL\/CSA ratings, supplied in replacement fuse kit \u003cstrong\u003e1746-F9\u003c\/strong\u003e (5 fuses per kit).\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":67305957621875,"sku":"1746-OAP12","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/1746-OX8_Cocoai.jpg?v=1795595883","url":"https:\/\/www.dcssupplier.com\/ar\/products\/allen-bradley-1746-oap12-slc-500-12-pt-ac-output-module","provider":"DcsSupplier Limited","version":"1.0","type":"link"}