{"product_id":"allen-bradley-1747-l20b-slc-500-fixed-plc-controller","title":"Allen-Bradley 1747-L20B SLC 500 Fixed PLC Controller","description":"\u003cp\u003eThe \u003cstrong\u003e1747-L20B\u003c\/strong\u003e is an Allen-Bradley SLC 500 fixed PLC controller with 20 integrated I\/O points, comprising 12 inputs rated for 120 V AC and 8 AC TRIAC outputs. It operates from a 120-240 V AC line supply and supports an optional two-slot expansion chassis. The controller also provides LED status indication, battery-backed RAM and selectable UVPROM or EEPROM program backup.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eI\/O Configuration and Electrical Characteristics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe controller combines 12 AC input channels with 8 TRIAC output channels in a fixed hardware configuration. Unlike DC-input versions of the SLC 500 fixed controllers, the 1747-L20B is designed for 120 V AC input signals.\u003c\/p\u003e\n\u003cp\u003eIts 120-240 V AC line supply is separate from the field input and output specifications. The controller has a maximum apparent power requirement of 50 VA and uses 1.25 A fuse protection for the AC supply.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eProcessing and Memory\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 1747-L20B has a processor program scan time of 8 ms per 1K of program instructions. Its programming memory is limited to 1024 bytes, making memory capacity an important consideration when evaluating existing application requirements.\u003c\/p\u003e\n\u003cp\u003eThe controller uses lithium battery-backed RAM with a stated battery assembly life of 5 years. Capacitor backup provides approximately 2 weeks of retention, while program backup options include UVPROM (Ultraviolet Programmable Read-Only Memory) or EEPROM (Electrically Erasable Programmable Read-Only Memory).\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eExpansion and Communication Connections\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eAn optional two-slot expansion chassis is supported, allowing additional hardware expansion beyond the controller's integrated I\/O configuration. The specified connection hardware includes a 6-pin Phoenix connector, and the listed communication cable is Belden 9463.\u003c\/p\u003e\n\u003cp\u003eThe controller does not include a high-speed counter. This limitation should be considered when evaluating applications that require high-frequency pulse counting or dedicated high-speed event processing.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eStatus Indication and Installation\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe front-panel LED indicators display three controller conditions:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRUN: Indicates the controller's operating status.\u003c\/li\u003e\n\u003cli\u003eCPU FAULT: Indicates a processor fault condition.\u003c\/li\u003e\n\u003cli\u003eFORCED I\/O: Indicates that I\/O forcing is active.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe controller mounts to an enclosure back panel using its mounting tabs and either #12 or #10 screws. The original technical information also specifies that the protective insulation covering the circuit board should not be removed.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eEnvironmental and Operating Conditions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 1747-L20B is specified for operation between 0 and 60 deg C, with relative humidity of 5-95% non-condensing. Its non-operating storage temperature range is -40 to 85 deg C.\u003c\/p\u003e\n\u003cp\u003eThe stated environmental resistance includes 30 G operational shock and 2.5 G vibration over a frequency range of 10-500 Hz. These ratings are relevant when checking the controller against the mechanical and environmental conditions of its installation location.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1747-L20B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Line\u003c\/td\u003e\n\u003ctd\u003eSLC 500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eFixed Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal I\/O Points\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInputs\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003eAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e120 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutputs\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eAC TRIAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine Power\u003c\/td\u003e\n\u003ctd\u003e120-240 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Apparent Power\u003c\/td\u003e\n\u003ctd\u003e50 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Supply Fuse Protection\u003c\/td\u003e\n\u003ctd\u003e1.25 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHigh-Speed Counter\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Capability\u003c\/td\u003e\n\u003ctd\u003eOptional two-slot expansion chassis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProgram Scan Time\u003c\/td\u003e\n\u003ctd\u003e8 ms per 1K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Program Memory\u003c\/td\u003e\n\u003ctd\u003e1024 bytes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRAM Backup\u003c\/td\u003e\n\u003ctd\u003eLithium battery-backed RAM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Assembly Life\u003c\/td\u003e\n\u003ctd\u003e5 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCapacitor Backup Duration\u003c\/td\u003e\n\u003ctd\u003e2 weeks\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProgram Backup Options\u003c\/td\u003e\n\u003ctd\u003eUVPROM or EEPROM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad-Dependent Holdup Time\u003c\/td\u003e\n\u003ctd\u003e20-700 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLED Status Indicators\u003c\/td\u003e\n\u003ctd\u003eRUN, CPU FAULT, FORCED I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Cable\u003c\/td\u003e\n\u003ctd\u003eBelden 9463\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector\u003c\/td\u003e\n\u003ctd\u003e6-pin Phoenix connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCircuit Wire Size\u003c\/td\u003e\n\u003ctd\u003e24 AWG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption per Point\u003c\/td\u003e\n\u003ctd\u003e0.27 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply Loading\u003c\/td\u003e\n\u003ctd\u003e10.5-15.0 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5-95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperational Shock\u003c\/td\u003e\n\u003ctd\u003e30 G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration Resistance\u003c\/td\u003e\n\u003ctd\u003e2.5 G at 10-500 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise Immunity Standard\u003c\/td\u003e\n\u003ctd\u003eNEMA ICS2-230\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eUL-listed, CSA-certified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eBack-panel mounting tabs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Screws\u003c\/td\u003e\n\u003ctd\u003e#12 or #10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e4.13 lbs (1.87 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the difference between the 1747-L20B and a DC-input SLC 500 controller?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The 1747-L20B has 12 inputs rated for 120 V AC and 8 AC TRIAC outputs. DC-input models use different field input signal requirements, so input wiring and electrical compatibility must be checked before selecting a replacement.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the 1747-L20B support high-speed counting?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No. The listed specifications explicitly identify the controller as having no high-speed counter. Applications requiring dedicated high-speed counting should use a controller with a verified compatible counting function.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What program backup options are available?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The controller supports UVPROM or EEPROM program backup options and uses lithium battery-backed RAM. The specified capacitor backup duration is approximately 2 weeks, while the lithium battery assembly has a stated 5-year life.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the 1747-L20B be expanded?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. An optional two-slot expansion chassis is specified. The exact supported expansion modules and configuration limits should be checked against the applicable SLC 500 documentation before installation.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":67305972465779,"sku":"1747-L20B","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/1747-L20N_Cocoai_2be8f284-fa67-4b5e-a01c-62c4ed1b8a22.jpg?v=1795596636","url":"https:\/\/www.dcssupplier.com\/ar\/products\/allen-bradley-1747-l20b-slc-500-fixed-plc-controller","provider":"DcsSupplier Limited","version":"1.0","type":"link"}