{"product_id":"allen-bradley-1791-32a0-block-i-o-ac-input-module","title":"Allen-Bradley 1791-32A0 Block I\/O AC Input Module","description":"\u003cp\u003eThe \u003cstrong\u003e1791-32A0\u003c\/strong\u003e is a 32-channel AC input module from the Allen-Bradley 1791 Block I\/O series. Designed for 120 VAC discrete signal monitoring, it provides four groups of eight inputs and communicates with a programmable controller through a Remote I\/O (RIO) interface. The module includes configurable communication settings, input status indicators, and electrical isolation between I\/O groups and the logic circuitry.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eInput Configuration and Signal Characteristics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 1791-32A0 provides 32 AC input channels arranged in four groups of eight. Each input operates with a nominal voltage of 120 VAC and accepts signals within a 79-132 VAC range at 47-63 Hz.\u003c\/p\u003e\n\u003cp\u003eThe input specifications distinguish between nominal current and switching thresholds. Nominal input current is 11.0 mA, while the minimum ON-state current is 5 mA at 79 V and 60 Hz. The maximum ON-state current is 12.3 mA at 132 V and 60 Hz.\u003c\/p\u003e\n\u003cp\u003eEach channel has a maximum OFF-state voltage of 35 V and a minimum OFF-state current of 2.3 mA at 60 Hz. Input impedance is 15 kOhm maximum at 60 Hz. These values are relevant when matching field devices and evaluating the electrical conditions required for reliable input-state detection.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eRemote I\/O Communication\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe module uses a Remote I\/O communication interface to exchange input data with a compatible PLC system. Its communication and status indicators help maintenance personnel identify communication conditions and module faults.\u003c\/p\u003e\n\u003cp\u003eTwo switch assemblies provide configuration settings for parameters such as the starting I\/O group, rack addressing, last-state selection, and communication rate. For SLC 500 applications, the installation documentation specifies communication through a compatible 1747-SN I\/O Scanner.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eElectrical Isolation and Power Requirements\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 1791-32A0 requires an external supply of 85-132 VAC at 47-63 Hz, with a specified current requirement of 150 mA. Its isolation ratings are 500 VAC between the power supply and RIO interface, and 1250 VAC between I\/O groups and between I\/O groups and logic.\u003c\/p\u003e\n\u003cp\u003eThe module has a maximum power dissipation of 13.62 W and maximum thermal dissipation of 46.44 BTU\/hr. These ratings should be considered when planning the installation enclosure and ventilation.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eWiring and Mounting\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe module has removable terminal strips on its left and right sides for input, power, grounding, and RIO connections. It supports DIN rail or panel mounting, providing two installation options for existing control panel layouts.\u003c\/p\u003e\n\u003cp\u003eFor field wiring, the manufacturer specifies stranded conductors up to 14 AWG (2 mm2), with maximum insulation thickness of 3\/64 inch (1.2 mm). The equipment grounding stud must be connected to the equipment ground according to the installation instructions.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1791-32A0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Line\u003c\/td\u003e\n\u003ctd\u003e1791 Block I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003e1791 Block I\/O Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eAC Discrete Input Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Inputs\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Groups\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInputs per Group\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Outputs\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Input Voltage\u003c\/td\u003e\n\u003ctd\u003e120 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Input Current\u003c\/td\u003e\n\u003ctd\u003e11.0 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eON-State Voltage Range\u003c\/td\u003e\n\u003ctd\u003e79-132 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Frequency\u003c\/td\u003e\n\u003ctd\u003e47-63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eON-State Current\u003c\/td\u003e\n\u003ctd\u003e5 mA minimum at 79 V, 60 Hz; 12.3 mA maximum at 132 V, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOFF-State Voltage\u003c\/td\u003e\n\u003ctd\u003e35 V maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOFF-State Current\u003c\/td\u003e\n\u003ctd\u003e2.3 mA minimum at 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e15 kOhm maximum at 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal Delay\u003c\/td\u003e\n\u003ctd\u003e1.0 ms OFF-to-ON; 26 ms maximum ON-to-OFF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eRemote I\/O (RIO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply Voltage\u003c\/td\u003e\n\u003ctd\u003e85-132 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply Frequency\u003c\/td\u003e\n\u003ctd\u003e47-63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Supply Current\u003c\/td\u003e\n\u003ctd\u003e150 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Dissipation\u003c\/td\u003e\n\u003ctd\u003e13.62 W maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermal Dissipation\u003c\/td\u003e\n\u003ctd\u003e46.44 BTU\/hr maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply-to-RIO Isolation\u003c\/td\u003e\n\u003ctd\u003e500 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Group-to-Group Isolation\u003c\/td\u003e\n\u003ctd\u003e1250 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Group-to-Logic Isolation\u003c\/td\u003e\n\u003ctd\u003e1250 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN Rail or Panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e6.95 x 4.35 x 3.85 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e176.5 x 110.5 x 98 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWire Size\u003c\/td\u003e\n\u003ctd\u003e14 AWG (2 mm2) stranded maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Wire Insulation Thickness\u003c\/td\u003e\n\u003ctd\u003e3\/64 in (1.2 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5-95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.31 lbs (1.05 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUPC\u003c\/td\u003e\n\u003ctd\u003e612598124800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer Status\u003c\/td\u003e\n\u003ctd\u003eDiscontinued \/ Obsolete\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How many input channels does the Allen-Bradley 1791-32A0 provide?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: It provides 32 AC discrete input channels arranged in four groups of eight. All channels are designed for nominal 120 VAC input signals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What communication interface does the 1791-32A0 use?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The module uses Allen-Bradley Remote I\/O (RIO) communication. For SLC 500 systems, the installation documentation identifies the 1747-SN Series A I\/O Scanner as the required communication interface. It also specifies that the module is not compatible with the 1747-DSN Distributed I\/O Scanner.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the difference between the ON-state and OFF-state input specifications?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The ON-state voltage range is 79-132 VAC, while the maximum OFF-state voltage is 35 V. The minimum ON-state current is 5 mA at 79 V and 60 Hz. These thresholds help determine whether connected AC field signals will be correctly recognized.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the 1791-32A0 still manufactured?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No. The model is discontinued by Allen-Bradley. Surplus and refurbished units may still be available through industrial automation spare-parts suppliers. Verify the product revision and physical condition when sourcing an obsolete unit.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDocumentation\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe following original manufacturer documentation provides additional technical and installation information:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRockwell Automation - 1791-32A0\/B Product Data\u003c\/li\u003e\n\u003cli\u003e1791-32A0 Series B Installation Instructions\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":67332328980595,"sku":"1791-32A0","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/1791-32A0_Cocoai_1.jpg?v=1795758240","url":"https:\/\/www.dcssupplier.com\/ar\/products\/allen-bradley-1791-32a0-block-i-o-ac-input-module","provider":"DcsSupplier Limited","version":"1.0","type":"link"}