{"product_id":"allen-bradley-1792d-8bvt8d-devicenet-combination-i-o","title":"Allen-Bradley 1792D-8BVT8D DeviceNet Combination I\/O","description":"\u003cp\u003eThe \u003cstrong\u003e1792D-8BVT8D\u003c\/strong\u003e is a combination digital I\/O module in the Allen-Bradley 1792 ArmorBlock MAXUM series. It provides eight sinking\/sourcing digital inputs and eight sourcing digital outputs, with connector-level diagnostics for output connections. Using DeviceNet communication, the module connects distributed field signals to a compatible PLC control system. The model is discontinued by the manufacturer.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eI\/O Configuration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 1792D-8BVT8D combines input monitoring and output control in one distributed I\/O block. Its eight digital inputs accept signals from compatible field devices, while eight sourcing outputs provide switching control signals to connected loads.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e8 sinking\/sourcing inputs:\u003c\/strong\u003e Support discrete input signal monitoring.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e8 sourcing outputs:\u003c\/strong\u003e Provide sourcing-type switching outputs.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector-level diagnostics:\u003c\/strong\u003e Provide diagnostic information associated with the output connectors, helping identify connection or output-related faults.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe combination configuration allows input and output signals to be handled at the same field location without requiring separate input and output blocks.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eDeviceNet Communication\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe module uses DeviceNet to exchange I\/O data with the PLC controller. Input states are transferred to the controller, while output commands are received over the network and applied to the connected field devices.\u003c\/p\u003e\n\u003cp\u003eWhen integrating this module into an existing system, verify the DeviceNet node configuration, network wiring, communication settings, and controller support. The connector-level diagnostic feature should also be considered when checking the output wiring and field connection status.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1792D-8BVT8D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Series\u003c\/td\u003e\n\u003ctd\u003e1792 ArmorBlock MAXUM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDeviceNet Combination I\/O Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Configuration\u003c\/td\u003e\n\u003ctd\u003e8 Inputs \/ 8 Outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Digital Inputs\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003eSinking\/Sourcing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Digital Outputs\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eSourcing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Diagnostics\u003c\/td\u003e\n\u003ctd\u003eConnector-Level Diagnostics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Network\u003c\/td\u003e\n\u003ctd\u003eDeviceNet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.55 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer Status\u003c\/td\u003e\n\u003ctd\u003eDiscontinued\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e\u003cstrong\u003eConnector-Level Diagnostics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe connector-level diagnostic capability is a notable feature of this model. It provides diagnostic information at the output connector level rather than limiting fault identification to the overall module status.\u003c\/p\u003e\n\u003cp\u003eThis distinction is useful during maintenance because technicians can investigate output connection conditions more directly. However, the exact diagnostic conditions, fault indicators, and recovery procedures should be verified against the applicable product documentation.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How many I\/O points does the 1792D-8BVT8D provide?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The module provides 16 digital I\/O points in total: eight sinking\/sourcing inputs and eight sourcing outputs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the purpose of connector-level diagnostics?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Connector-level diagnostics provide output connection-related diagnostic information, helping maintenance personnel identify potential problems at individual output connectors. Specific diagnostic codes and fault conditions depend on the product documentation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the 1792D-8BVT8D operate with a DeviceNet PLC system?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. It is designed for DeviceNet communication with a compatible control system. The controller configuration, network settings, and I\/O mapping must be verified before installation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the 1792D-8BVT8D still manufactured?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No. The supplied product information identifies it as discontinued. The listing specifies a Radwell 2-year warranty, while the original manufacturer's factory warranty does not apply.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":67332386226291,"sku":"1792D-8BVT8D","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/1792D-8BVT8D_Cocoai_6b327581-547e-469f-921c-60cf58a17a3a.jpg?v=1795758595","url":"https:\/\/www.dcssupplier.com\/ar\/products\/allen-bradley-1792d-8bvt8d-devicenet-combination-i-o","provider":"DcsSupplier Limited","version":"1.0","type":"link"}