{"product_id":"allen-bradley-190e-and2-cb40c-ky-r-combination-motor-starter","title":"Allen-Bradley 190E-AND2-CB40C-KY-R Combination Motor Starter","description":"\u003cp\u003eThe \u003cstrong\u003e190E-AND2-CB40C-KY-R\u003c\/strong\u003e from Allen-Bradley (Rockwell Automation) is an open-style direct-on-line (DOL) combination motor starter with an integrated 100-C09 contactor and 140M-C2E high-break motor protection circuit breaker. It is configured for a 2.5-4.0 A current range and a 110 V AC \/ 50 Hz or 120 V AC \/ 60 Hz contactor coil, with a lockable red\/yellow operating knob and an RC coil surge suppressor.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eMotor Switching and Protection\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 190E Eco Starter combines contactor-based motor switching with motor circuit protection. The 100-C09 contactor controls the connection and disconnection of the motor supply, while the 140M-C2E motor protection circuit breaker provides circuit protection.\u003c\/p\u003e\n\u003cp\u003eThe 2.5-4.0 A current range is relevant when matching the starter to the connected motor. The protection setting must correspond to the motor nameplate current and the applicable motor protection requirements.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eContactor and Auxiliary Contacts\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe assembly uses a 100-C09 contactor with a 110 V AC, 50 Hz \/ 120 V AC, 60 Hz coil. Its auxiliary contact configuration includes \u003cstrong\u003e1 normally open (NO) contact\u003c\/strong\u003e for control and status signaling.\u003c\/p\u003e\n\u003cp\u003eThe 140M circuit breaker configuration includes \u003cstrong\u003e1 NO and 1 normally closed (NC) auxiliary contact\u003c\/strong\u003e. These contacts provide additional circuit status signals for external control circuits and electrical interlocking arrangements.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eOperator and Coil Protection\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe KY configuration specifies a \u003cstrong\u003elockable red\/yellow twist knob\u003c\/strong\u003e for the circuit breaker operator. This provides a manually operated, lockable control arrangement for the starter assembly.\u003c\/p\u003e\n\u003cp\u003eThe final R suffix identifies an \u003cstrong\u003eRC coil surge suppressor\u003c\/strong\u003e. This accessory suppresses voltage transients associated with contactor coil switching and helps limit electrical disturbances in the coil control circuit.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e190E-AND2-CB40C-KY-R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley \/ Rockwell Automation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eECO Combination Motor Starter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStarter Type\u003c\/td\u003e\n\u003ctd\u003eDirect-On-Line (DOL)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Range\u003c\/td\u003e\n\u003ctd\u003e2.5-4.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContactor\u003c\/td\u003e\n\u003ctd\u003e100-C09\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContactor Coil Voltage\u003c\/td\u003e\n\u003ctd\u003e110 V AC, 50 Hz \/ 120 V AC, 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContactor Auxiliary Contacts\u003c\/td\u003e\n\u003ctd\u003e1 NO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMotor Protection Circuit Breaker\u003c\/td\u003e\n\u003ctd\u003e140M-C2E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCircuit Breaker Frame\u003c\/td\u003e\n\u003ctd\u003eC-frame, High Break\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCircuit Breaker Auxiliary Contacts\u003c\/td\u003e\n\u003ctd\u003e1 NO + 1 NC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperator Configuration\u003c\/td\u003e\n\u003ctd\u003eLockable Twist Knob, Red\/Yellow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoil Surge Suppressor\u003c\/td\u003e\n\u003ctd\u003eRC Type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConstruction\u003c\/td\u003e\n\u003ctd\u003eOpen Style\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003e35 mm DIN Rail Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Connections\u003c\/td\u003e\n\u003ctd\u003eScrew Connections\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUPC \/ GTIN\u003c\/td\u003e\n\u003ctd\u003e10611320338628\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e\u003cstrong\u003eOrdering Code Configuration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe catalog number identifies the main components and factory configuration:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e190E:\u003c\/strong\u003e Direct-on-line starter with motor protection circuit breaker.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eA:\u003c\/strong\u003e 100-C09 contactor size.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eN:\u003c\/strong\u003e Open-style mounting configuration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eD:\u003c\/strong\u003e 110 V AC at 50 Hz \/ 120 V AC at 60 Hz coil voltage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e2:\u003c\/strong\u003e One normally open contactor auxiliary contact.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eC:\u003c\/strong\u003e C-frame circuit breaker.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eB40:\u003c\/strong\u003e 2.5-4.0 A circuit breaker current range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eC:\u003c\/strong\u003e One NO and one NC circuit breaker auxiliary contact.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKY:\u003c\/strong\u003e Lockable red\/yellow twist knob.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eR:\u003c\/strong\u003e RC coil surge suppressor.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis configuration information is useful when identifying the complete assembly or checking a replacement against an existing installation. The complete suffix should be retained when specifying the product.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the current adjustment range of the 190E-AND2-CB40C-KY-R?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The motor protection circuit breaker has a 2.5-4.0 A current range. Its setting should be selected according to the connected motor's nameplate current and protection requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What do the KY and R suffixes mean?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: KY identifies the lockable red\/yellow twist knob, while R identifies the RC coil surge suppressor. Both are part of the specified configuration and should be considered when selecting a replacement.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What control voltage does this motor starter require?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The contactor coil is rated for 110 V AC at 50 Hz or 120 V AC at 60 Hz. The control supply must match the applicable voltage and frequency rating.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":67311738814579,"sku":"190E-AND2-CB40C-KY-R","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/190E-MNZ242-CB40X_Cocoai.jpg?v=1795659097","url":"https:\/\/www.dcssupplier.com\/ar\/products\/allen-bradley-190e-and2-cb40c-ky-r-combination-motor-starter","provider":"DcsSupplier Limited","version":"1.0","type":"link"}