{"product_id":"allen-bradley-2094-bc07-m05-kinetix-6000-integrated-axis-module","title":"Allen Bradley 2094-BC07-M05 Kinetix 6000 Integrated Axis Module","description":"\u003cp\u003eThe \u003cstrong\u003eAllen Bradley 2094-BC07-M05\u003c\/strong\u003e is an Integrated Axis Module (IAM) in the Kinetix 6000 multi-axis servo drive family. It combines a converter and inverter section to supply DC bus power and control servo motor operation in multi-axis motion systems. The module supports a three-phase AC input of 324-528 V rms and provides 45 kW of continuous power output to the DC bus.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003ePower Supply and DC Bus Operation\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 2094-BC07-M05 accepts three-phase AC input power and provides DC bus power for connected axis modules. Its separate single-phase control power input operates independently of the main power input, allowing the control electronics to receive power within the specified voltage range.\u003c\/p\u003e\n\u003cp\u003eThe module monitors DC bus voltage against overvoltage and undervoltage thresholds. Its internal shunt circuit dissipates regenerated energy during motor deceleration, helping manage DC bus voltage when connected servo axes return energy to the common bus.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eServo Drive Performance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe inverter section provides a continuous output current of 34.6 A rms, equivalent to 48.9 A sine-wave peak current. The converter section supports 45 kW of continuous power output to the bus, with peak output ratings dependent on the drive series.\u003c\/p\u003e\n\u003cp\u003eThe module has a specified line-loss ride-through time of 20 milliseconds. This parameter indicates the supported interval for maintaining operation during a temporary loss of incoming AC line power, subject to the system operating conditions.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eInternal Shunt and Power Dissipation\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe integrated shunt circuit has a continuous power rating of 200 W and a peak power rating of 22,300 W according to the supplied technical specifications. The specified shunt turn-on voltage is 805 VDC, and the internal shunt resistor value is 28.75 ohms.\u003c\/p\u003e\n\u003cp\u003ePower dissipation varies with drive utilization, ranging from 71 W at 20% utilization to 226 W at 100% utilization. These values should be considered when determining enclosure cooling and thermal management requirements.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eElectrical Connections and System Integration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe IAM module provides connections for control power, DC bus, motor power and motor brake circuits. The front panel includes a power-applied indicator and a node address selector for module identification and configuration.\u003c\/p\u003e\n\u003cp\u003eThe supplied description identifies Logix5000 controllers and EtherNet\/IP connectivity as part of the Kinetix 6000 system architecture. The exact communication interface and network connection arrangement should be verified against the applicable module series and system configuration.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e2094-BC07-M05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Line\u003c\/td\u003e\n\u003ctd\u003eKinetix 6000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Description\u003c\/td\u003e\n\u003ctd\u003eIntegrated Axis Module (IAM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eAxis Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCategory\u003c\/td\u003e\n\u003ctd\u003eDrives\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Input Voltage\u003c\/td\u003e\n\u003ctd\u003e324-528 V rms, three-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal AC Input Voltage\u003c\/td\u003e\n\u003ctd\u003e360-480 V rms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Input Frequency\u003c\/td\u003e\n\u003ctd\u003e47-63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Input Current\u003c\/td\u003e\n\u003ctd\u003e71.0 A rms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Inrush Current\u003c\/td\u003e\n\u003ctd\u003e62.2 A (0-peak)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Voltage\u003c\/td\u003e\n\u003ctd\u003e95-264 V rms, single-phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Control Voltage\u003c\/td\u003e\n\u003ctd\u003e110-240 V rms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Input Voltage (Common-Bus Follower)\u003c\/td\u003e\n\u003ctd\u003e458-747 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Input Current (Common-Bus Follower)\u003c\/td\u003e\n\u003ctd\u003e67.7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBus Overvoltage\u003c\/td\u003e\n\u003ctd\u003e825 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBus Undervoltage\u003c\/td\u003e\n\u003ctd\u003e275 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous Power Output to Bus\u003c\/td\u003e\n\u003ctd\u003e45 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeak Power Output to Bus\u003c\/td\u003e\n\u003ctd\u003e90 kW (Series A); 135 kW (Series B, S and D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous Output Current to Bus\u003c\/td\u003e\n\u003ctd\u003e67.7 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeak Output Current to Bus\u003c\/td\u003e\n\u003ctd\u003e135.4 A (Series A); 203.2 A (Series B, C and D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInverter Section Output\u003c\/td\u003e\n\u003ctd\u003e49 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous Output Current (rms)\u003c\/td\u003e\n\u003ctd\u003e34.6 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous Output Current (sine, 0-peak)\u003c\/td\u003e\n\u003ctd\u003e48.9 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEfficiency\u003c\/td\u003e\n\u003ctd\u003e95% (technical specifications); 97% (product description)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLine Loss Ride Through\u003c\/td\u003e\n\u003ctd\u003e20 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Shunt Continuous Power\u003c\/td\u003e\n\u003ctd\u003e200 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Shunt Peak Power\u003c\/td\u003e\n\u003ctd\u003e22,300 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Shunt Turn-On Voltage\u003c\/td\u003e\n\u003ctd\u003e805 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Shunt Resistance\u003c\/td\u003e\n\u003ctd\u003e28.75 ohms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConverter Inductance\u003c\/td\u003e\n\u003ctd\u003e75 uH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConverter Capacitance\u003c\/td\u003e\n\u003ctd\u003e1,410 uF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-Circuit Current Rating\u003c\/td\u003e\n\u003ctd\u003e200,000 A rms symmetrical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Dissipation at 20% Utilization\u003c\/td\u003e\n\u003ctd\u003e71 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Dissipation at 40% Utilization\u003c\/td\u003e\n\u003ctd\u003e101 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Dissipation at 60% Utilization\u003c\/td\u003e\n\u003ctd\u003e137 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Dissipation at 80% Utilization\u003c\/td\u003e\n\u003ctd\u003e179 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Dissipation at 100% Utilization\u003c\/td\u003e\n\u003ctd\u003e226 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Input Fuse\u003c\/td\u003e\n\u003ctd\u003eFNQ-R-10 (10 A) or FNQ-R-7.5 (7.5 A)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Input Circuit Breaker\u003c\/td\u003e\n\u003ctd\u003e1492-SPM2D060 or 1492-SPM1D150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDC Bus Power Fuse\u003c\/td\u003e\n\u003ctd\u003eBussmann FWJ-125A (manufacturer information requires confirmation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0-50 deg C (32-122 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Clearance\u003c\/td\u003e\n\u003ctd\u003e80 mm (3.10 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e9.98 kg (22.00 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e\u003cstrong\u003eProtection and Configuration Considerations\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe supplied product description lists several safety-related functions, including zero-speed monitoring, safe stopping, maximum-speed monitoring, direction monitoring, door monitoring and safe maximum-acceleration monitoring. These functions should not automatically be interpreted as certified safety functions integrated into this IAM module. Their implementation and required safety hardware must be confirmed against the actual system configuration.\u003c\/p\u003e\n\u003cp\u003eFuse selection and circuit protection must follow the applicable Kinetix 6000 installation requirements. The specified control input fuses, circuit breakers and DC bus fuse should be checked against the complete drive configuration before replacement or installation.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the function of the Allen Bradley 2094-BC07-M05?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: It is an Integrated Axis Module in the Kinetix 6000 servo drive family. It converts incoming three-phase AC power into DC bus power and provides inverter functionality for servo motor control in a multi-axis motion system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the difference between the continuous and peak bus output ratings?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The continuous bus output rating is 45 kW. Peak output capability depends on the drive series: 90 kW for Series A and 135 kW for Series B, S and D. The corresponding peak output current ratings also vary by series.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the 2094-BC07-M05 be used with other Kinetix 6000 axis modules?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The IAM is designed to provide DC bus power within a multi-axis drive architecture. However, the exact compatible axis modules, power supply arrangement and series requirements must be checked against the applicable Kinetix 6000 documentation before assembling or modifying a system.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":67332743266419,"sku":"2094-BC07-M05","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/2094-AMP5-S3_Cocoai_6f44e113-af3d-4299-8d07-dc905b7cc27c.jpg?v=1795760545","url":"https:\/\/www.dcssupplier.com\/ar\/products\/allen-bradley-2094-bc07-m05-kinetix-6000-integrated-axis-module","provider":"DcsSupplier Limited","version":"1.0","type":"link"}