{"product_id":"allen-bradley-2706-nc13-dataliner-programming-cable","title":"Allen-Bradley 2706-NC13 Dataliner Programming Cable","description":"\u003cp\u003eThe \u003cstrong\u003eAllen-Bradley 2706-NC13\u003c\/strong\u003e is an RS-232 serial programming cable designed to connect a compatible computer or programming terminal to Bulletin 2706 Dataliner DL5 and DL40 message displays. It features female DB9 connectors at both ends, with a 3 m (10 ft) cable length. The cable supports serial communication for operating and programming the Dataliner display.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e2706-NC13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eDataliner RS-232 Programming Cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Displays\u003c\/td\u003e\n\u003ctd\u003eDataliner DL5 and DL40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Host Devices\u003c\/td\u003e\n\u003ctd\u003eIBM AT or compatible computer, Allen-Bradley 6121 Industrial PC\/AT, Allen-Bradley 1745-T50 terminal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interface\u003c\/td\u003e\n\u003ctd\u003eRS-232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Configuration\u003c\/td\u003e\n\u003ctd\u003eFemale DB9 to Female DB9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003e9-pin D-shell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e3 m (10 ft)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.55 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer Status\u003c\/td\u003e\n\u003ctd\u003eDiscontinued\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e\u003cstrong\u003eCommunication and Compatibility\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 2706-NC13 provides a physical serial connection between the Dataliner display's RS-232 port and a compatible programming device. For computer connections, the host-side connector is connected to the serial RS-232 port (COM 1). The cable is specifically identified for IBM AT-compatible computers and the Allen-Bradley 6121 Industrial PC\/AT and 1745-T50 terminal configurations.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eConnection Requirements\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe Dataliner communication port and the host serial port must use matching baud rates. Allen-Bradley specifies that DL5 and DL40 displays were shipped with a default baud rate of 9600 baud, although previously configured units may use a different setting.\u003c\/p\u003e\n\u003cp\u003eBefore connecting the cable, disconnect power to the Dataliner display. Connect one end to its RS-232 port and the other to the appropriate serial port on the computer or programming terminal. Power can be restored after both connections are in place.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Which Dataliner displays are compatible with the 2706-NC13?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The cable is specified for Allen-Bradley Bulletin 2706 Dataliner DL5 and DL40 message displays. Host compatibility must also be checked, as the 2706-NC13 is designed for specific 9-pin serial computer and terminal configurations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What baud rate should be used with the 2706-NC13?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The host serial port baud rate must match the Dataliner display setting. The factory default for DL5 and DL40 displays is 9600 baud, but the actual configured value should be checked before programming.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the 2706-NC13 still manufactured by Allen-Bradley?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The 2706-NC13 is listed as discontinued by the manufacturer. Existing units may be sourced through surplus or aftermarket inventory, subject to product condition and availability.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":67311858679923,"sku":"2706-NC13","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/2706-NC13_Cocoai_dbd3764f-45e9-46da-bfaf-004f45718f93.jpg?v=1795660260","url":"https:\/\/www.dcssupplier.com\/ar\/products\/allen-bradley-2706-nc13-dataliner-programming-cable","provider":"DcsSupplier Limited","version":"1.0","type":"link"}