{"product_id":"allen-bradley-2711-t6c2l1-panelview-standard-operator-interface","title":"Allen-Bradley 2711-T6C2L1 PanelView Standard Operator Interface","description":"\u003cp\u003eConfigured for real-time human-machine interaction in Allen-Bradley automation environments, the \u003cstrong\u003eAllen-Bradley 2711-T6C2L1\u003c\/strong\u003e (\u003cstrong\u003e2711-T6C2\u003c\/strong\u003e PanelView Standard Operator Interface) provides direct physical\/electrical execution. Designed to process operator input and display system telemetry, this 5.7-inch color active matrix terminal translates analog resistive touch actions into high-speed command frames delivered over DH-485 network architectures directly to connected PLC memory addresses.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e2711-T6C2L1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.01 lbs (0.91 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e5.7 in Display Diagonal (320 x 234 Pixels)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C (32 to 131 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 W max (24 VDC Nominal, 18 to 32 VDC Range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Type\u003c\/td\u003e\n\u003ctd\u003eColor Active Matrix TFT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Mechanism\u003c\/td\u003e\n\u003ctd\u003eAnalog Resistive Touch Screen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Ports\u003c\/td\u003e\n\u003ctd\u003eDH-485 Communication Port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Category\u003c\/td\u003e\n\u003ctd\u003eHMI \/ MMI \/ OIT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSub-Category\u003c\/td\u003e\n\u003ctd\u003eOperator Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eFirmware Flash Compatibility \u0026amp; Control Loop Integration\u003c\/h3\u003e\n\u003cp\u003eOperating directly within deterministic DH-485 control topologies, the terminal's onboard protocol driver maintains high-frequency polling loops with host controllers such as SLC 500 and MicroLogix processors. Internal screen buffer memory accelerates multi-page graphics switching while maintaining low-latency data updates for alarm logs and system trends. The galvanically isolated DH-485 port guards internal processor logic against industrial ground potential shifts, suppressing differential noise during high-density I\/O scanning cycles.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What input power voltage range is required to power the 2711-T6C2L1 terminal?\u003c\/p\u003e\n\u003cp\u003eA: The terminal requires a 24 VDC power source operating within an allowable input range of 18 VDC to 32 VDC. Connecting to 120\/240 VAC power sources will damage internal circuitry.\u003c\/p\u003e\n\u003cp\u003eQ: How does the 2711-T6C2L1 interface with the PLC network?\u003c\/p\u003e\n\u003cp\u003eA: The unit connects directly via an integrated DH-485 communication port, exchanging bit and word data tables directly with compatible Allen-Bradley programmable logic controllers.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eDisconnect all primary power supplies from the control cabinet enclosure before beginning installation or panel cutout procedures.\u003c\/li\u003e\n\u003cli\u003eCut a clean, rectangular opening in the enclosure door matching the standard PanelView 600 panel cutout dimensions.\u003c\/li\u003e\n\u003cli\u003eCheck that the continuous rear perimeter gasket is fully seated within its channel before inserting the terminal into the panel cutout.\u003c\/li\u003e\n\u003cli\u003eSlide the terminal into the cutout and tighten all mounting clips uniformly to the recommended torque specification to ensure a NEMA 4X\/12 ingress protection seal.\u003c\/li\u003e\n\u003cli\u003eConnect a dedicated heavy-gauge grounding conductor from the chassis grounding terminal directly to the main system earth ground bus prior to energizing the 24 VDC power leads.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":66750117118067,"sku":"2711-T6C2L1","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/2711-T6C3L1_92672862-5d1b-4b93-87e6-943faf7d7618.png?v=1790748561","url":"https:\/\/www.dcssupplier.com\/ar\/products\/allen-bradley-2711-t6c2l1-panelview-standard-operator-interface","provider":"DcsSupplier Limited","version":"1.0","type":"link"}