{"product_id":"allen-bradley-2711-t9c3-panelview-standard-900-terminal","title":"Allen-Bradley 2711-T9C3 PanelView Standard 900 Terminal","description":"\u003cp\u003eThe \u003cstrong\u003eAllen-Bradley 2711-T9C3\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e2711-T9C3\u003c\/strong\u003e Operator Terminal, operates as a dedicated hardware component for process visualization and operator command execution within DH-485 network platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e2711-T9C3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e3.09 kg (6.81 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard PanelView 900 enclosure profile\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e85-264 VAC (120 VAC nominal), 39 Watts \/ 133 BTU\/hr heat dissipation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Type\u003c\/td\u003e\n\u003ctd\u003e9-inch Color Active Matrix TFT Display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e640 x 480 pixels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperator Input\u003c\/td\u003e\n\u003ctd\u003eResistive Touchscreen (24 x 16 cell grid, 1 million presses)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNonvolatile Memory\u003c\/td\u003e\n\u003ctd\u003e1008 KB nonvolatile application memory, 240 KB runtime memory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Ports\u003c\/td\u003e\n\u003ctd\u003eDH-485 port and RS-232 Printer port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Rating\u003c\/td\u003e\n\u003ctd\u003eNEMA Type 4X (Indoor), 12, 13, IP54, IP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEtherNet\/IP Networks and I\/O Density Scaling\u003c\/h3\u003e\n\u003cp\u003eThe operator terminal executes direct data table access across multi-node DH-485 networks while routing telemetry to upstream enterprise layers through EtherNet\/IP deterministic networks via protocol translation modules. Designed to streamline control architecture and support scalable panel I\/O density, the terminal processes 384 touch cell inputs to execute logic writes without requiring additional controller ladder logic routines. Integrated firmware flash compatibility guarantees deterministic animation refresh, alarm logging, and direct serial printing across industrial automation systems.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What line power voltage does the 2711-T9C3 terminal require?\u003c\/p\u003e\n\u003cp\u003eA: The terminal features a universal AC power supply supporting an input voltage range of 85-264 VAC at 50\/60 Hz (120 VAC nominal).\u003c\/p\u003e\n\u003cp\u003eQ: How is physical communication established between the 2711-T9C3 and a host PLC?\u003c\/p\u003e\n\u003cp\u003eA: The terminal utilizes an integrated DH-485 port to establish point-to-point or multi-node communication with SLC 500 or MicroLogix controllers, often using a 1747-UIC converter cable.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eEnsure all AC mains supply power is isolated and locked out before placing the terminal into the panel cutout. Tighten all mounting levers evenly around the chassis perimeter to compress the sealing gasket, ensuring NEMA 4X \/ IP65 enclosure integrity. Route DH-485 network cables in grounded metal conduits separated from VFD power outputs and high-voltage motor lines to prevent communication corruption from high-frequency electromagnetic interference.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":66881178370163,"sku":"2711-T9C3","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/2711-T9C9_Cocoai_764a1192-8fad-4808-a1b5-e33ec6ce8c0f.jpg?v=1792134917","url":"https:\/\/www.dcssupplier.com\/ar\/products\/allen-bradley-2711-t9c3-panelview-standard-900-terminal","provider":"DcsSupplier Limited","version":"1.0","type":"link"}