{"product_id":"allen-bradley-2711-t9c8-panelview-900-standard-operator-terminal","title":"Allen-Bradley 2711-T9C8 PanelView 900 Standard Operator Terminal","description":"\u003cp\u003eThe \u003cstrong\u003eAllen-Bradley 2711-T9C8\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e2711-T9C8\u003c\/strong\u003e Operator Terminal, operates as a dedicated hardware component for process visualization and real-time control input execution within Data Highway Plus (DH+) PLC networks.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eBase Catalog\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eScreen Type \/ Size\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eCommunication Port\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eAuxiliary Port\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e2711-T9\u003c\/td\u003e\n\u003ctd\u003eTouch \/ 9-inch Color TFT\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003eC8\u003c\/strong\u003e: Data Highway Plus (DH+)\u003c\/td\u003e\n\u003ctd\u003eRS-232 Printer Port\u003c\/td\u003e\n\u003ctd\u003e85 to 264 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e2711-T9C8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e3.35 kg (7.38 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard PanelView 900 panel cutout frame\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eHeat dissipation 39 W (132 BTU\/hr)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Size\u003c\/td\u003e\n\u003ctd\u003e9 Inches (210 x 131 mm display area)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Type\u003c\/td\u003e\n\u003ctd\u003eActive Matrix Color TFT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Resolution\u003c\/td\u003e\n\u003ctd\u003e640 x 480 pixels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTouch Matrix\u003c\/td\u003e\n\u003ctd\u003e384 cells (24 columns x 16 rows)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e85 to 264 VAC, 47 to 63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication Memory\u003c\/td\u003e\n\u003ctd\u003e240 KB (Prior to Series E); 1008 KB (Series E and later)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Communication\u003c\/td\u003e\n\u003ctd\u003eData Highway Plus (DH+)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuxiliary Port\u003c\/td\u003e\n\u003ctd\u003eRS-232 Printer Port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity and Network Integration\u003c\/h3\u003e\n\u003cp\u003eThe 2711-T9C8 interfaces with legacy PLC-5 and SLC 5\/04 platforms via an integrated Data Highway Plus (DH+) node, executing deterministic network data packet transfers at 57.6k, 115.2k, or 230.4k baud over Belden 9463 twinaxial cabling. Internal logic processing coordinates high I\/O density scaling and static memory addresses directly to the graphics engine, avoiding backplane bus latency during alarm log writes to the auxiliary RS-232 printer interface. Onboard firmware flash compatibility permits seamless application runtime execution across Series A through F hardware revisions.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What cable is required for connecting the primary DH+ communication port?\u003c\/p\u003e\n\u003cp\u003eA: The primary DH+ port uses standard 3-wire Belden 9463 (blue hose) cable or Allen-Bradley 1770-CD cable, terminated at the terminal using a standard 3-pin phoenix connector.\u003c\/p\u003e\n\u003cp\u003eQ: Can the RS-232 printer port be reconfigured for uploading\/downloading application files?\u003c\/p\u003e\n\u003cp\u003eA: No. The auxiliary RS-232 port on the 2711-T9C8 is dedicated solely to serial printer communication for real-time alarm and trigger event printing.\u003c\/p\u003e\n\u003cp\u003eQ: How is application memory expanded between Series D and Series E hardware builds?\u003c\/p\u003e\n\u003cp\u003eA: Application memory is hardware-fixed on the main circuit assembly; Series A through D modules contain 240 KB of non-volatile application flash, while Series E and higher contain 1008 KB.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003ePanel Cutout and Gasket Installation: Cut the panel opening per PanelView 900 template dimensions. Ensure the perimeter seal gasket is fully seated into the rear bezel channel to achieve the intended NEMA\/IP ingress rating.\u003c\/li\u003e\n\u003cli\u003eClamp Tightening Protocol: Insert panel mounting clips into the slots around the perimeter of the chassis. Tighten screws evenly in a star pattern to a specified torque of 1.13 N-m (10 in-lb) to prevent housing deflection.\u003c\/li\u003e\n\u003cli\u003eAC Power Wiring: Connect AC line, neutral, and protective earth conductors to the designated terminal block terminals. Verify supply voltage stays strictly within the 85 to 264 VAC range.\u003c\/li\u003e\n\u003cli\u003eDH+ Cable Termination and Shielding: Maintain proper line polarity on the DH+ blue hose conductors (Clear to Pin 1, Shield to Pin 2, Blue to Pin 3). Connect the cable shield ground at one end of the network segment only to prevent ground loop noise.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":45459882082419,"sku":"2711-T9C8","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/2711-T9C8_Cocoai_d12281e9-8e39-433e-90a6-700d85e1df13.jpg?v=1788835649","url":"https:\/\/www.dcssupplier.com\/ar\/products\/allen-bradley-2711-t9c8-panelview-900-standard-operator-terminal","provider":"DcsSupplier Limited","version":"1.0","type":"link"}