{"product_id":"allen-bradley-2711p-t15c4a9-panelview-plus-6-operator-interface-terminals","title":"Allen-Bradley 2711P-T15C4A9 PanelView Plus 6 Operator Interface Terminals","description":"\u003cp\u003eThe \u003cstrong\u003eAllen-Bradley 2711P-T15C4A9\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e2711P-T15C4A9\u003c\/strong\u003e Operator Interface Terminal, operates as a dedicated hardware component for human-machine visualization and control execution within EtherNet\/IP and ControlLogix automation network platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e2711P-T15C4A9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e5.10 kg (11.25 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard PanelView Plus 6 1500 Cutout Dimensions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to +55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e160 VA max (65 VA typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e15.0 inch Color Active-Matrix TFT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e1024 x 768 Pixels, 18-bit color\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Method\u003c\/td\u003e\n\u003ctd\u003e8-wire Analog Resistive Touch Screen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMemory\u003c\/td\u003e\n\u003ctd\u003e512 MB RAM, 512 MB Non-volatile (79 MB User Flash)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOnboard Ports\u003c\/td\u003e\n\u003ctd\u003e1x Ethernet (10\/100Base-T), 1x RS-232, 2x USB Host\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Network Velocity and Firmware Scaling\u003c\/h3\u003e\n\u003cp\u003eThe operator interface utilizes Ethernet and RS-232 communication channels to establish deterministic networks with host PLCs, maintaining steady I\/O density scaling during continuous runtime telemetry polling. Integrated firmware flash compatibility supports dense graphical displays without degrading backplane bus communication velocity or key-press touch execution cycles. Processing hardware executes high-frequency screen updates while preserving isolation across industrial noise-prone power bus lines.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the backlight in the 2711P-T15C4A9 display be replaced in the field?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the backlight component is field-replaceable using part number 2711P-RL15C when operating life limits are reached.\u003c\/p\u003e\n\u003cp\u003eQ: What input power source does the 2711P-T15C4A9 accept?\u003c\/p\u003e\n\u003cp\u003eA: The terminal incorporates an internal AC power supply rated for 100 to 240 VAC input at 50 to 60 Hz line frequency.\u003c\/p\u003e\n\u003cp\u003eQ: How is application runtime memory structured within this unit?\u003c\/p\u003e\n\u003cp\u003eA: The system provides 512 MB of onboard RAM and 512 MB of non-volatile storage, offering approximately 79 MB of unreserved flash memory dedicated to user project files.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure Mounting\u003c\/strong\u003e: Secure the terminal into an enclosure cutout using the standard mounting levers, tightening them in an alternating cross pattern to ensure an IP66\/NEMA 4X liquid-tight front seal.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAC Line Wiring\u003c\/strong\u003e: Connect AC line and neutral supply leads to the internal terminal block, ensuring input line voltage remains strictly within the 100 to 240 VAC limits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding and Grounding\u003c\/strong\u003e: Connect a low-impedance copper ground conductor from the terminal ground stud directly to the main chassis earth ground busbar to mitigate transient noise interference on serial and network ports.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":66895224242291,"sku":"2711P-T15C4A9","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/2711P-RBT15_e0165e3b-a8cd-439a-99a5-95b514da5495.png?v=1792228597","url":"https:\/\/www.dcssupplier.com\/ar\/products\/allen-bradley-2711p-t15c4a9-panelview-plus-6-operator-interface-terminals","provider":"DcsSupplier Limited","version":"1.0","type":"link"}