{"product_id":"bently-nevada-990-05-xx-01-ru-147202-01-vibration-transmitter","title":"Bently Nevada 990-05-XX-01-RU 147202-01 Vibration Transmitter","description":"\u003cp\u003eConfigured for high-fidelity signal conditioning and loop current translation in machinery protection systems, the \u003cstrong\u003eBently Nevada 990-05-XX-01-RU 147202-01\u003c\/strong\u003e (\u003cstrong\u003e990-05-XX-01-RU 147202-01\u003c\/strong\u003e Vibration Transmitter) provides direct physical\/electrical execution. It transforms raw dynamic displacement telemetry from a non-contacting proximity probe into a standardized analog output natively at the device tier to communicate machinery health metrics parallel to master monitoring rack execution bus cycles.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e990-05-XX-01-RU 147202-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eBently Nevada\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.44 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e10 cm x 7.3 cm x 5 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Input\u003c\/td\u003e\n\u003ctd\u003eSingle 3300 NSv Proximity Probe and extension cable configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperational Input Voltage\u003c\/td\u003e\n\u003ctd\u003e+12 to +35 VDC at the transmitter terminal block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Output Profile\u003c\/td\u003e\n\u003ctd\u003e4-20 mA proportional analog vibration loop current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibrated Probe Gap Window\u003c\/td\u003e\n\u003ctd\u003e0.5 mm to 1.75 mm from target face for full-scale output range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFault Detection Loop\u003c\/td\u003e\n\u003ctd\u003eIntegrated \"Not OK\" \/ Signal Defeat hardware circuitry\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Seal\u003c\/td\u003e\n\u003ctd\u003ePotted construction supporting up to 100% condensing humidity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Profile\u003c\/td\u003e\n\u003ctd\u003e35 mm DIN-rail clips or direct bulkhead mounting screw options\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eMachinery Monitoring \u0026amp; Sensor Signal Integration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEddy-Current Probe Scaling and Transduction:\u003c\/strong\u003e The transmitter generates an RF excitation signal directed to the 3300 NSv Proximity Probe tip. As the target shaft alters the magnetic field, the internal conditioning electronics translate the changing impedance into an eddy-current probe scaling format, which is then linearized and converted to a proportional 4-20 mA loop current.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGap Voltage Validation and Operational Windows:\u003c\/strong\u003e Field calibration routines require the target-to-probe gap to remain strictly within the 0.5 mm to 1.75 mm threshold. This ensures the baseline DC gap voltage validation sits cleanly inside the transmitter's linear conversion zone, preventing signal clipping or clipping-induced harmonic errors on the output current loop.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCross-Talk Suppression and Fault Mitigation:\u003c\/strong\u003e The integrated Not OK \/ Signal Defeat circuit actively monitors driver integrity. If an open or short circuit occurs at the probe connection, the transmitter forces the loop current below 3.6 mA, achieving localized cross-talk suppression and blocking false alarms at the control system.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What specific hardware behaviors manifest if the connection between the 3300 NSv probe and the 147202-01 transmitter is broken?\u003c\/p\u003e\n\u003cp\u003eA: The internal monitoring logic trips the Not OK loop circuit, shifting the output signal down below 3.6 mA. This loop clamping immediately signals a hardware fault to the host control interface, locking out the alarm circuit to prevent false machine trips caused by loose wiring.\u003c\/p\u003e\n\u003cp\u003eQ: Can this 0.44 kg potted transmitter handle direct immersion or continuous water sprays without external enclosures?\u003c\/p\u003e\n\u003cp\u003eA: While the internal circuitry features an industrial potted design that withstands up to 100% condensing humidity environments, the exposed screw terminal blocks do not possess an IP ingress rating for direct liquid spray. The module must be housed in a sealed NEMA 4X or IP65 terminal box if liquid splashing is present.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":45130052108403,"sku":"990-05-XX-01-RU 147202-01","price":233.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/QQ20260420-171119.png?v=1782286525","url":"https:\/\/www.dcssupplier.com\/ar\/products\/bently-nevada-990-05-xx-01-ru-147202-01-vibration-transmitter","provider":"DcsSupplier Limited","version":"1.0","type":"link"}