{"product_id":"block-i-o-modules-allen-bradley-1791-8ac","title":"Block I\/O Modules | Allen-Bradley 1791-8AC","description":"\u003cp\u003eThe Allen-Bradley \u003cstrong\u003e1791-8AC\u003c\/strong\u003e is a 16-point AC Block I\/O module from the 1791 Block I\/O product line. It provides 8 discrete 120 VAC inputs and 8 AC outputs, with a Remote I\/O (RIO) adapter for communication with compatible Allen-Bradley controller systems. The module supports distributed I\/O operation through a three-wire RIO network.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eI\/O Configuration and Signal Operation\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 1791-8AC combines eight discrete AC input channels and eight AC output channels in one block. Input signals are monitored locally and transmitted to the controller through the RIO network, while output commands received from the controller operate the connected field devices.\u003c\/p\u003e\n\u003cp\u003eThe input ON-state voltage range is 79-132 VAC, with a minimum ON-state current of 5 mA at 79 VAC. The specified maximum OFF-state voltage is 35 VAC, and the minimum OFF-state current is 2.3 mA. These thresholds help distinguish valid input states when checking field wiring and signal compatibility.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eRemote I\/O Communication\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe module operates as a Remote I\/O adapter using Allen-Bradley's RIO protocol. The network uses a three-wire connection with Belden 9463 cable or an approved equivalent, and supports daisy-chain topology for connecting remote I\/O devices.\u003c\/p\u003e\n\u003cp\u003eThe supplied technical information identifies compatibility with legacy PLC-2, PLC-3 and PLC-5 platforms, as well as RIO-enabled SLC 500 processors equipped with a 1747-SN Remote I\/O Scanner module. This is a legacy communication architecture and should not be confused with modern EtherNet\/IP-based I\/O systems.\u003c\/p\u003e\n\u003cp\u003eBTR (Block Transfer Read) and BTW (Block Transfer Write) instructions support data exchange between the controller and remote I\/O. The supplied description states that up to 32 read and write message arrays can be used and connected in parallel for larger data transfers.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eAC Output Characteristics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe eight output channels are rated for AC loads, with a stated output voltage range of 20-132 VAC in the detailed description. Output current capacity depends on mounting orientation and ambient temperature.\u003c\/p\u003e\n\u003cp\u003eAt 30-60 deg C, the stated output current ranges are 300-600 mA for vertical mounting and 150-300 mA for horizontal mounting. The module also specifies a 10 A surge current for 50 ms, recurring every 2 seconds, subject to a minimum ON-state output current of 50 mA per output.\u003c\/p\u003e\n\u003cp\u003eThe maximum ON-state voltage drop is 1.5 V at 300 mA, and OFF-state leakage current is specified at 3 mA. The stated switching delays are 1 ms from OFF to ON and 8.3 ms from ON to OFF at 60 Hz.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003ePower, Mounting and Electrical Isolation\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe 1791-8AC uses an external AC supply to power the module and its local backplane. The specified external supply voltage range is 85-132 VAC, with an external power current requirement of 150 mA.\u003c\/p\u003e\n\u003cp\u003eVertical and horizontal mounting orientations are supported, but the output current capability varies with orientation. The specified maximum power dissipation is 12.9 W, corresponding to a maximum thermal dissipation of 43.99 BTU\/hr.\u003c\/p\u003e\n\u003cp\u003eThe module has a stated isolation voltage of 500 VAC, tested at 1250 VAC between I\/O groups and between the I\/O group and logic circuitry. These isolation specifications describe the module's electrical separation and dielectric test conditions.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e1791-8AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Line\u003c\/td\u003e\n\u003ctd\u003e1791 Block I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eBlock I\/O Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e1791-8AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUPC\u003c\/td\u003e\n\u003ctd\u003e612598127061\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal I\/O Points\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Inputs\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Outputs\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003eDiscrete AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Voltage\u003c\/td\u003e\n\u003ctd\u003e120 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput ON-State Voltage\u003c\/td\u003e\n\u003ctd\u003e79-132 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput ON-State Current\u003c\/td\u003e\n\u003ctd\u003e5 mA minimum at 79 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput OFF-State Voltage\u003c\/td\u003e\n\u003ctd\u003e35 VAC maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput OFF-State Current\u003c\/td\u003e\n\u003ctd\u003e2.3 mA minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e20-132 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current, Vertical Mounting\u003c\/td\u003e\n\u003ctd\u003e300-600 mA at 30-60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current, Horizontal Mounting\u003c\/td\u003e\n\u003ctd\u003e150-300 mA at 30-60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Surge Current\u003c\/td\u003e\n\u003ctd\u003e10 A for 50 ms, recurring every 2 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum ON-State Output Current\u003c\/td\u003e\n\u003ctd\u003e50 mA per output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum ON-State Voltage Drop\u003c\/td\u003e\n\u003ctd\u003e1.5 V at 300 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOFF-State Leakage Current\u003c\/td\u003e\n\u003ctd\u003e3 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOFF-to-ON Signal Delay\u003c\/td\u003e\n\u003ctd\u003e1 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eON-to-OFF Signal Delay\u003c\/td\u003e\n\u003ctd\u003e8.3 ms at 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Protocol\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley Remote I\/O (RIO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRIO Cable\u003c\/td\u003e\n\u003ctd\u003eBelden 9463 or approved equivalent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRIO Network Topology\u003c\/td\u003e\n\u003ctd\u003eDaisy-chain\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Power Voltage\u003c\/td\u003e\n\u003ctd\u003e85-132 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Power Current\u003c\/td\u003e\n\u003ctd\u003e150 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Orientation\u003c\/td\u003e\n\u003ctd\u003eVertical \/ Horizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Power Dissipation\u003c\/td\u003e\n\u003ctd\u003e12.9 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Thermal Dissipation\u003c\/td\u003e\n\u003ctd\u003e43.99 BTU\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Voltage\u003c\/td\u003e\n\u003ctd\u003e500 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDielectric Test Voltage\u003c\/td\u003e\n\u003ctd\u003e1250 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e176.5 x 68.8 x 98 mm (6.95 x 2.7 x 3.85 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eConflicting values in supplied source; see editorial note\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Lifecycle Status\u003c\/td\u003e\n\u003ctd\u003eDiscontinued \/ Obsolete\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Which Allen-Bradley controllers are compatible with the 1791-8AC?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The supplied product description identifies PLC-2, PLC-3 and PLC-5 controller platforms, along with RIO-enabled SLC 500 processors using the 1747-SN Remote I\/O Scanner. Compatibility should be checked against the specific controller configuration and RIO network requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the 1791-8AC be mounted horizontally or vertically?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. Both orientations are specified, but the allowable output current differs. At 30-60 deg C, the stated output current ranges are 300-600 mA for vertical mounting and 150-300 mA for horizontal mounting.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the 1791-8AC use EtherNet\/IP communication?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No. The supplied description identifies Allen-Bradley Remote I\/O (RIO) as its communication protocol. It uses a three-wire network with Belden 9463 cable or an approved equivalent, rather than EtherNet\/IP.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the Allen-Bradley 1791-8AC still manufactured?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: No. The 1791-8AC is listed as discontinued\/obsolete. Surplus and refurbished units may be available through aftermarket industrial automation suppliers.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":67284846903411,"sku":"1791-8AC","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/1791-8BC_Cocoai_1_559ff911-6170-4572-9890-02ffd797adad.jpg?v=1795414792","url":"https:\/\/www.dcssupplier.com\/ar\/products\/block-i-o-modules-allen-bradley-1791-8ac","provider":"DcsSupplier Limited","version":"1.0","type":"link"}