{"product_id":"emerson-a6824r-ams-6500-communication-interface-module","title":"Emerson A6824R AMS 6500 Communication Interface Module","description":"\u003cp\u003eConfigured for centralized process data aggregation and industrial protocol distribution in AMS 6500 platforms, the \u003cstrong\u003eEmerson A6824R\u003c\/strong\u003e (\u003cstrong\u003eA6824R\u003c\/strong\u003e Communication Interface Module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eEmerson A6824R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEmerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eStandard Module Weight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e3U Eurocard Form Factor, 4 TE Width\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eStandard AMS 6500 Environmental Limits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 V DC via backplane (approx 250 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlot Requirement\u003c\/td\u003e\n\u003ctd\u003e1 slot (IMR6500 rack)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModbus RTU Interface\u003c\/td\u003e\n\u003ctd\u003eRS-485, 19.2 kbaud, 8E1 format\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModbus TCP\/IP Interface\u003c\/td\u003e\n\u003ctd\u003eEthernet RJ-45 (10Base-T \/ 10\/100 Mbps)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRedundancy\u003c\/td\u003e\n\u003ctd\u003eDual communication paths supported\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDefault IP Address\u003c\/td\u003e\n\u003ctd\u003e192.168.255.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eCommunication Interface Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation \u0026amp; HART Loop Protocols\u003c\/h3\u003e\n\u003cp\u003eThe A6824R collects process values, alarm statuses, and individual channel health parameters across the internal rack backplane. Data conversion routines process inputs through isolated internal buses before outputting via Modbus RTU over RS-485 or Modbus TCP\/IP over Ethernet RJ-45 interfaces. Robust channel-to-channel isolation and structured protocol framing protect field bus lines against industrial noise, providing deterministic data delivery to connected host DCS and SCADA systems without signal interference.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How is primary operational power provided to the A6824R module?\u003c\/p\u003e\n\u003cp\u003eA: The card draws approximately 250 mA at 24 V DC directly from the internal AMS 6500 rack backplane.\u003c\/p\u003e\n\u003cp\u003eQ: What factory default IP address is pre-configured on the Ethernet port?\u003c\/p\u003e\n\u003cp\u003eA: The default Ethernet interface IP address is set to 192.168.255.1 for initial configuration.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eInsert the 3U Eurocard 4 TE module firmly into its designated slot in the IMR6500 rack to ensure proper backplane connector seating.\u003c\/li\u003e\n\u003cli\u003eTighten upper and lower front-panel retaining screws to establish ground continuity and secure the module against vibration.\u003c\/li\u003e\n\u003cli\u003eConnect RS-485 wiring using shielded twisted-pair conductors terminated to specification for 19.2 kbaud Modbus RTU communication.\u003c\/li\u003e\n\u003cli\u003eVerify Ethernet link status via the RJ-45 connector LEDs before configuring dual redundant communication paths to the host controller.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Emerson Epro","offers":[{"title":"Default Title","offer_id":45467736965235,"sku":"EPRO A6824R","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/EPROA6824R_Cocoai.jpg?v=1789020000","url":"https:\/\/www.dcssupplier.com\/ar\/products\/emerson-a6824r-ams-6500-communication-interface-module","provider":"DcsSupplier Limited","version":"1.0","type":"link"}