{"product_id":"emerson-deltav-ve3006-md-plus-controller","title":"Emerson DeltaV VE3006 MD-PLUS Controller","description":"\u003cp\u003eThe \u003cstrong\u003eEmerson DeltaV VE3006\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eVE3006\u003c\/strong\u003e MD-PLUS Controller, operates as a dedicated hardware component for executing real-time distributed process control algorithms within DeltaV digital automation networks.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eVE3006\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEmerson DeltaV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.0 kg (Shipping Weight)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard DeltaV controller footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to 70 deg C (-40 to 158 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 deg C (-40 to 185 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Requirement\u003c\/td\u003e\n\u003ctd\u003eSupplied by System Power Supply through 2-wide Power\/Controller Carrier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuse Protection\u003c\/td\u003e\n\u003ctd\u003e3.0 A, non-replaceable fuses\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Dissipation\u003c\/td\u003e\n\u003ctd\u003e5.0 W typical, 7.0 W maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUser Memory\u003c\/td\u003e\n\u003ctd\u003e48 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMechanical Shock\u003c\/td\u003e\n\u003ctd\u003e10 g 1\/2-sine wave for 11 ms (normal operating conditions)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eOn right slot of power\/controller carrier\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control and DCS Loop Execution\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e4-20 mA HART Loop Protocol Pass-Through\u003c\/strong\u003e: Decodes variable data from connected 4-20 mA HART smart field instruments, linking process diagnostics directly with the main logic task execution loop.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFOUNDATION Fieldbus Connectivity\u003c\/strong\u003e: Functions as the central communications link for managing digital signals originating from FOUNDATION Fieldbus and Profibus PA segment couplers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel-to-Channel Isolation Control\u003c\/strong\u003e: Prevents high-frequency electrical disturbances from crossing from the external network interfaces into the internal control processing logic.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eControl Loop Processing Execution\u003c\/strong\u003e: Leverages 48 MB of user memory to run complex analog, discrete, and batch logic processes within local controller nodes.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How is the internal power protection configured on the VE3006 controller?\u003c\/p\u003e\n\u003cp\u003eA: The VE3006 is equipped with a internal, non-replaceable 3.0 A fuse to protect the internal circuitry against overcurrent transients from the carrier power bus.\u003c\/p\u003e\n\u003cp\u003eQ: Can the VE3006 controller be inserted or removed under active backplane power?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The hardware is designed to support online, hot-swap installation and removal on the right slot of a powered 2-wide Power\/Controller Carrier without disrupting adjacent system power modules.\u003c\/p\u003e\n\u003cp\u003eQ: What action should be taken if the internal 3.0 A fuse trips?\u003c\/p\u003e\n\u003cp\u003eA: Because the fuse is non-replaceable, any overcurrent event that blows the fuse requires a complete module replacement to restore operation.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower\/Controller Carrier Slotting\u003c\/strong\u003e: Ensure the VE3006 is aligned with the right-side slot of the 2-wide Power\/Controller Carrier. Press down firmly until the lock mechanisms click to establish full contact with the power backplane.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal and Humidity Protection\u003c\/strong\u003e: Mount the carrier inside an industrial enclosure that regulates the environment to prevent condensation, maintaining relative humidity between 5% and 95% and temperatures within the -40 to 70 deg C limits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Shock Mitigation\u003c\/strong\u003e: In installations subject to continuous vibration or physical shock, ensure the DIN rail is rigidly anchored to the backplate to keep operational mechanical shock below the 10 g (11 ms half-sine wave) specification limit.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":45238982705267,"sku":"VE3006","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/102_0686797e-c62a-472c-bec7-1a147cfec678.png?v=1784099839","url":"https:\/\/www.dcssupplier.com\/ar\/products\/emerson-deltav-ve3006-md-plus-controller","provider":"DcsSupplier Limited","version":"1.0","type":"link"}