{"product_id":"emerson-ic200pwr102j-versamax-power-supply-module","title":"Emerson IC200PWR102J VersaMax Power Supply Module","description":"\u003cp\u003eThe \u003cstrong\u003eEmerson IC200PWR102J\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIC200PWR102\u003c\/strong\u003e Power Supply Module, operates as a dedicated hardware component for localized backplane power distribution within VersaMax platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC200PWR102J\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEmerson (GE Fanuc)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.31 lbs (0.14 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard VersaMax Module Form Factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e27 VA Input Power\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e85-132 VAC (120 VAC nominal) \/ 176-264 VAC (240 VAC nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Frequency\u003c\/td\u003e\n\u003ctd\u003e47-63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e5 VDC and 3.3 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current\u003c\/td\u003e\n\u003ctd\u003e1.5 A total max (1.5 A max @ 5 VDC; 1.0 A max @ 3.3 VDC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHoldup Time\u003c\/td\u003e\n\u003ctd\u003e20 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection\u003c\/td\u003e\n\u003ctd\u003eBuilt-in Short Circuit and Overload Protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEmerson Technical Characteristics\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Bus Communication Velocity\u003c\/strong\u003e: Delivers regulated 5 VDC and 3.3 VDC power rails directly to the VersaMax backplane bus, maintaining logic voltage stability across connected CPU, NIU, and I\/O modules during rapid switching operations.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/O Density Scaling\u003c\/strong\u003e: Acts as a primary or supplemental power supply when mounted on a Power Supply Booster carrier, permitting expanded backplane current distribution across high-density I\/O clusters without logic drops.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How is the primary input voltage range configured on the IC200PWR102J hardware?\u003c\/p\u003e\n\u003cp\u003eA: Input voltage selection is set via jumper terminals on the right side of the ground connection: installing the jumper sets operation for 120 VAC nominal (85-132 VAC range), while removing the jumper configures the unit for 240 VAC nominal (176-264 VAC range).\u003c\/p\u003e\n\u003cp\u003eQ: What is the maximum combined output current capacity of the IC200PWR102J backplane power rails?\u003c\/p\u003e\n\u003cp\u003eA: The total combined output current across both the 5 VDC and 3.3 VDC supply rails must not exceed 1.5 A total maximum.\u003c\/p\u003e\n\u003cp\u003eQ: Does the IC200PWR102J include built-in protection against fault conditions on the backplane output rails?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The module contains internal circuitry providing short-circuit and overload protection to guard logic modules against line fault conditions.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eEnsure all primary AC mains power sources are completely isolated before attempting to insert, remove, or wire the IC200PWR102J power supply module.\u003c\/li\u003e\n\u003cli\u003eVerify the physical jumper configuration corresponds strictly to the supplied line voltage (jumper installed for 120 VAC nominal, uninstalled for 240 VAC nominal) prior to energizing the module.\u003c\/li\u003e\n\u003cli\u003eFasten the power supply securely to the carrier base to establish continuous ground path integrity across the DIN-rail mounting frame.\u003c\/li\u003e\n\u003cli\u003eRoute AC input line conductors in a separate pathway away from sensitive low-voltage I\/O lines to avoid coupling high-frequency power switching electrical noise.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":45338792427635,"sku":"IC200PWR102J","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/screenshot_2026-08-10_15-14-11_9668cfb3-ef3f-4ee6-a5b1-0bbc52c539c3.png?v=1786347077","url":"https:\/\/www.dcssupplier.com\/ar\/products\/emerson-ic200pwr102j-versamax-power-supply-module","provider":"DcsSupplier Limited","version":"1.0","type":"link"}