{"product_id":"emerson-kj3001x1-ba1-129p549x152-input-modules","title":"EMERSON KJ3001X1-BA1 129P549X152 Input Modules","description":"\u003cp\u003eThe \u003cstrong\u003eEmerson KJ3001X1-BA1 129P549X152\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eKJ3001X1-BA1\u003c\/strong\u003e Discrete Input Module, operates as a dedicated hardware component for 24 VDC field signal acquisition within DeltaV M-Series platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eKJ3001X1-BA1 (129P549X152)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEmerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA \/ Global Manufacturing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eStandard Module Weight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eDeltaV M-Series Form Factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e12 VDC at 100 mA (LocalBus Power)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eDeltaV M-Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Circuit Rating\u003c\/td\u003e\n\u003ctd\u003e24 VDC at 5 mA per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e8-channel isolated discrete input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKeying Position\u003c\/td\u003e\n\u003ctd\u003ePosition B2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95 percent (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHazardous Area Rating\u003c\/td\u003e\n\u003ctd\u003eII 3 G \/ EEx nA IIC T4 (Zone 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Rating\u003c\/td\u003e\n\u003ctd\u003eG3-class corrosive environments (ISA-S71.04-1985)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock \/ Vibration\u003c\/td\u003e\n\u003ctd\u003e10g shock (11 ms); 1 mm P-P (5-16 Hz), 0.5g (16-150 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol and Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe discrete input module features galvanic isolation barriers between field-side circuits and backplane system logic. This isolation prevents electrical noise transients, high-voltage surges, and earth ground potential loops from propagating into the central processing architecture. Designed to preserve system-to-channel isolation protocols across the DeltaV M-Series backplane, the module maintains uncorrupted signal integrity for low-voltage digital status detection alongside analog and 4-20 mA HART signal lines.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does this module support hot-swapping during live system operation?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the module supports hot-swapping in non-hazardous or Zone 2 environments when installed in accordance with approved DeltaV power supply safety protocols.\u003c\/p\u003e\n\u003cp\u003eQ: What mechanical feature prevents incorrect module insertion into a terminal block?\u003c\/p\u003e\n\u003cp\u003eA: The module incorporates mechanical rotary keying set to Position B2 to prevent incorrect module-to-terminal block mating.\u003c\/p\u003e\n\u003cp\u003eQ: What is the current draw per channel on the 24 VDC field signal circuit?\u003c\/p\u003e\n\u003cp\u003eA: Each individual field circuit is rated for 24 VDC at 5 mA per channel.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eWear proper ESD protection grounding straps prior to extracting or handling the module.\u003c\/li\u003e\n\u003cli\u003eVerify that the terminal block mechanical keying is aligned to Position B2 before inserting the module.\u003c\/li\u003e\n\u003cli\u003ePush the module firmly onto the DeltaV terminal block base until the retention latches engage completely.\u003c\/li\u003e\n\u003cli\u003eRoute field signal wiring using shielded cabling and ground shields at designated terminal points to minimize EMI\/RFI interference.\u003c\/li\u003e\n\u003cli\u003eEnsure cabinet environmental controls maintain operating temperatures within 0 to 60 deg C and humidity within 5 to 95 percent RH.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":45438072324211,"sku":"KJ3001X1-BA1 129P549X152","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/VE3007_2_3ef93274-9cb0-44fe-9add-9fabaa3f2c4b.png?v=1788415347","url":"https:\/\/www.dcssupplier.com\/ar\/products\/emerson-kj3001x1-ba1-129p549x152-input-modules","provider":"DcsSupplier Limited","version":"1.0","type":"link"}