{"product_id":"emerson-se3051c0-deltav-s-series-hardware","title":"Emerson SE3051C0 DeltaV S-Series Hardware","description":"\u003cp\u003eThe \u003cstrong\u003eEmerson SE3051C0\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eSE3051\u003c\/strong\u003e Controller Carrier, operates as a dedicated hardware component for structural support, backplane bus continuity, and control power routing within Emerson DeltaV S-Series distributed control systems.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSE3051C0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEmerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePart Number\u003c\/td\u003e\n\u003ctd\u003e12P4683X032 \/ KJ4005X1-BA1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.99 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e22.9 x 10.2 x 6.3 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Input\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Capacity\u003c\/td\u003e\n\u003ctd\u003e15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal Power Bus\u003c\/td\u003e\n\u003ctd\u003e12 VDC at 15 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary\/Secondary Distribution\u003c\/td\u003e\n\u003ctd\u003e12 A per bus (Maximum 3 A per card)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlot Configuration\u003c\/td\u003e\n\u003ctd\u003e2-Wide (Supports 2 system power supplies or controllers)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIngress Protection\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control Integration and DCS Instrument Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel-to-Channel Isolation Integration:\u003c\/strong\u003e The backplane structure isolates bulk logic power from the localized I\/O communication pathways, preventing transverse electrical faults from propagating across adjacent processing modules.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIntegrated Shield Grounding:\u003c\/strong\u003e The design incorporates a structural metal shield ground bar optimized to collect and drain stray high-frequency electromagnetic field noise directly away from the logic bus and control power conductors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTool-Free Snap-In Architecture:\u003c\/strong\u003e The structural rail hooks lock directly onto standard T-type DIN rails, allowing horizontal physical coupling with adjacent 8-wide I\/O carriers without the necessity of specialized installation tools.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can an individual controller or power module be online-expanded or replaced on the SE3051C0 carrier while the remainder of the DCS network is live?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The horizontal backplane design supports online module insertion and removal under power. Removing a single system controller or power supply from one slot will not interrupt bus power continuity or communications on the surviving node if configured in a redundant topology.\u003c\/p\u003e\n\u003cp\u003eQ: What is the maximum physical current handling capacity allowed per field power bus line across this carrier assembly?\u003c\/p\u003e\n\u003cp\u003eA: The integrated primary and secondary power distribution buses are rated for a maximum threshold of 12 A per bus line, with a hard consumption limit of 3 A maximum per connected slot card.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN-Rail Engagement:\u003c\/strong\u003e Mount the module horizontally to a continuous, grounded T-type DIN rail. Ensure that the integrated locking tabs fully audibly click into position before attaching adjacent I\/O expansion carriers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Supply Termination:\u003c\/strong\u003e Connect the bulk 24 VDC power lines using appropriate crimped ferrule terminals to ensure solid low-resistance physical contact. Tighten the power terminal plugs to the manufacturer's specified torque rating to prevent thermal degradation from loose physical connections.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Clearances:\u003c\/strong\u003e Maintain unobstructed perimeter spacing around the IP20 housing to ensure convective airflow matches the rated thermal gradient operating thresholds of -40 to 70 deg C.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":45245288808563,"sku":"SE3051C0","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/screenshot_2026-06-16_15-59-34_fefa33fe-238d-43d0-a2df-05cf39c0c2ec.png?v=1784189950","url":"https:\/\/www.dcssupplier.com\/ar\/products\/emerson-se3051c0-deltav-s-series-hardware","provider":"DcsSupplier Limited","version":"1.0","type":"link"}