{"product_id":"epro-con021-916-200-eddy-current-signal-converter","title":"EPRO CON021\/916-200 Eddy Current Signal Converter","description":"\u003cp\u003eThe \u003cstrong\u003eEPRO CON021\/916-200\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eCON021\/916-200\u003c\/strong\u003e Eddy Current Signal Converter, operates as a dedicated hardware component for radial and axial shaft displacement, position, eccentricity, and speed signal conditioning within turbo machinery monitoring systems.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCON021\/916-200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEPRO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.12 kg (~120 grams)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard DIN Signal Converter Frame\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-30 to +100 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eSupply Voltage -23 V to -32 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Interface\u003c\/td\u003e\n\u003ctd\u003ePR6426 Eddy Current Sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring Range\u003c\/td\u003e\n\u003ctd\u003e20.0 mm (Extended Range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal\u003c\/td\u003e\n\u003ctd\u003e-4 V to -20 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinearity Error\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 2.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Range\u003c\/td\u003e\n\u003ctd\u003e0 to 20000 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003eRise Time \u0026lt; 15 us\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Rating\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003e4 x M5x20 screws\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTerminal Connection\u003c\/td\u003e\n\u003ctd\u003eScrew terminals (max 1.5 mm2, wire-end sleeves)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eEddy Current Signal Converters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEddy-Current Probe Scaling \u0026amp; Gap Voltage Validation\u003c\/h3\u003e\n\u003cp\u003eThe CON021\/916-200 processes high-frequency signals generated by the paired PR6426 probe tip to measure displacement across an extended 20.0 mm dynamic range. Onboard signal processing scales eddy-current probe impedance variations into a linear -4 V to -20 V DC voltage output across a 0 to 20000 Hz frequency response spectrum. During mechanical setup, accurate gap voltage validation must be conducted to establish the baseline DC bias voltage, ensuring linear signal representation of dynamic rotor dynamics while maintaining cross-talk suppression relative to adjacent structural elements.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What power input range is required to energize the CON021\/916-200 converter?\u003c\/p\u003e\n\u003cp\u003eA: The module requires a nominal negative DC power supply ranging from -23 V DC to -32 V DC.\u003c\/p\u003e\n\u003cp\u003eQ: What wire gauge capacity do the connection terminals support?\u003c\/p\u003e\n\u003cp\u003eA: The screw terminal blocks accept conductors up to a maximum cross-section of 1.5 mm2 fitted with wire-end sleeves.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the unit using four M5x20 screws in a protective cabinet enclosure to satisfy IP20 environmental constraints.\u003c\/li\u003e\n\u003cli\u003eEnsure power supply conductors and probe signal leads are terminated with wire-end sleeves before clamping into the screw terminals.\u003c\/li\u003e\n\u003cli\u003eRoute sensor input cables separately from high-voltage AC lines to prevent signal distortion across the 0 to 20000 Hz frequency spectrum.\u003c\/li\u003e\n\u003cli\u003eVerify proper earth grounding of the signal conditioner frame to avoid ground loop noise during high-speed shaft measurement.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Emerson Epro","offers":[{"title":"Default Title","offer_id":45467724349555,"sku":"CON021\/916-200","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/CON021_PR6424002-010_2_ca3de836-054d-4f73-b605-92fa835075f0.jpg?v=1789019951","url":"https:\/\/www.dcssupplier.com\/ar\/products\/epro-con021-916-200-eddy-current-signal-converter","provider":"DcsSupplier Limited","version":"1.0","type":"link"}