{"product_id":"epro-con021-pr6423-013-000-displacement-system","title":"EPRO CON021+PR6423\/013-000 Displacement System","description":"\u003cp\u003eThe \u003cstrong\u003eEPRO CON021+PR6423\/013-000\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eCON021+PR6423\u003c\/strong\u003e Eddy Current Displacement System, operates as a dedicated hardware component for non-contact measurement of shaft displacement, vibration, and position within industrial rotating machinery platforms. It transforms microscopic dynamic physical movements of ferromagnetic steel targets into standardized voltage telemetry via an integrated transmitter block to communicate machinery health metrics parallel to master control network platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCON021+PR6423\/013-000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEPRO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eConfiguration dependent\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard EPRO module footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eConverter: -30 deg C to +100 deg C \/ Sensor: -35 deg C to +180 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e-23 VDC to -32 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Profile\u003c\/td\u003e\n\u003ctd\u003e-4 VDC to -20 VDC standard range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Range\u003c\/td\u003e\n\u003ctd\u003e0 to 20000 Hz (-3 dB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003eLess than 15 us\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDynamic Range\u003c\/td\u003e\n\u003ctd\u003e+\/- 2.0 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensitivity\u003c\/td\u003e\n\u003ctd\u003e8 V\/mm (203.2 mV\/mil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTarget Material\u003c\/td\u003e\n\u003ctd\u003eFerromagnetic steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure Resistance\u003c\/td\u003e\n\u003ctd\u003eUp to 10000 hPa (145 psi)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Material\u003c\/td\u003e\n\u003ctd\u003ePTFE insulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Rating\u003c\/td\u003e\n\u003ctd\u003eIP20 (Converter enclosure protection)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eATEX, IEC-Ex, CSA for hazardous areas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eMachinery Monitoring \u0026amp; TSI Signal Integration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEddy-Current Probe Scaling and Demodulation:\u003c\/strong\u003e The CON021 converter feeds an ultra-high frequency RF signal down the PTFE sensor line to drive the PR6423 coil tip. As the face of the target moves inside the magnetic flux layout, the converter demodulates impedance alterations back into a tight linear envelope, stabilizing the predefined 8 V\/mm eddy-current probe scaling factor down to 15 us response latencies.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGap Voltage Validation and Calibration Windows:\u003c\/strong\u003e Field validation routines track the raw DC bias component between -4 VDC and -20 VDC to determine the precise physical distance to the shaft. Keeping this gap voltage validation value at the correct operational setpoint ensures the dynamic vibration components stay centered within the +\/- 2.0 mm active tracking corridor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCross-Talk Suppression and Shield Isolation:\u003c\/strong\u003e High-density driver circuitry paths internal oscillator emissions away from neighboring modules to eliminate signal heterodyning. This cross-talk suppression strategy prevents parallel sensor cables inside joint wireways from cross-coupling and corrupting the primary voltage output paths.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What physical telemetry shifts occur if the connection between the CON021 converter and the PR6423 sensor drops open?\u003c\/p\u003e\n\u003cp\u003eA: The converter identifies the broken circuit line immediately and shifts its primary output voltage outside the normal operational envelope, dropping toward the supply rail limit. This voltage shift allows the supervisor PLC to register an instrumentation fault rather than an active high displacement shutdown event.\u003c\/p\u003e\n\u003cp\u003eQ: Can the CON021 converter module be mounted in areas with high ambient relative humidity without external enclosures?\u003c\/p\u003e\n\u003cp\u003eA: No. The converter module carries an IP20 rating, meaning its housing lacks protection against fluids and condensing moisture. It must be housed inside an IP65 or NEMA 4X rated field cabinet when placed in high-humidity processing areas to avoid shorting out the terminal block connections.\u003c\/p\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":45130033135731,"sku":"CON021+PR6423\/013-000","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/screenshot_2026-06-10_16-03-29_a262ca5e-cfb9-4629-a08e-7073349153f4.png?v=1782292648","url":"https:\/\/www.dcssupplier.com\/ar\/products\/epro-con021-pr6423-013-000-displacement-system","provider":"DcsSupplier Limited","version":"1.0","type":"link"}