{"product_id":"epro-con021-pr6424-013-030-transducer-system","title":"EPRO CON021+PR6424\/013-030 Transducer System","description":"\u003cp\u003eThe \u003cstrong\u003eEmerson CON021+PR6424\/013-030\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eCON021\u003c\/strong\u003e Signal Converter with \u003cstrong\u003ePR6424\u003c\/strong\u003e Eddy Current Sensor, operates as a dedicated hardware component for continuous shaft displacement and dynamic vibration processing within rotating machinery monitoring systems.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOption \/ Suffix\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eConfiguration Parameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eValue \/ Feature Description\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCON021\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter Base Model\u003c\/td\u003e\n\u003ctd\u003eExternal eddy current signal conditioning driver module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePR6424\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSensor Base Model\u003c\/td\u003e\n\u003ctd\u003eNon-contact eddy current proximity probe with 16 mm tip diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\/013\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProbe Configuration Code\u003c\/td\u003e\n\u003ctd\u003eM18 x 1.5 threaded stainless steel probe housing variant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-030\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCable Length Code\u003c\/td\u003e\n\u003ctd\u003eIntegral connection cable configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCON021+PR6424\/013-030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEmerson EPRO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eSensor tip diameter: 16 mm, Thread size: M18 x 1.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eProbe: -35 to +180 deg C, Converter: -30 to +100 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eSupply voltage: -23 VDC to -32 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatic Range\u003c\/td\u003e\n\u003ctd\u003eplus\/minus 2.0 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDynamic Range\u003c\/td\u003e\n\u003ctd\u003e0 to 1000 um\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensitivity\u003c\/td\u003e\n\u003ctd\u003e4 V\/mm (approx. 101.6 mV\/mil) plus\/minus 1.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Response\u003c\/td\u003e\n\u003ctd\u003eProbe: DC to 10 kHz, Converter bandwidth: 0 to 20 kHz (-3 dB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 15 us\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal\u003c\/td\u003e\n\u003ctd\u003e-4 VDC to -20 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Level\u003c\/td\u003e\n\u003ctd\u003eIP20 (Converter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing Material\u003c\/td\u003e\n\u003ctd\u003eStainless steel (Probe)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Format\u003c\/td\u003e\n\u003ctd\u003ePanel mount with M5 fixation points (Converter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Interfaces\u003c\/td\u003e\n\u003ctd\u003eLEMO sensor interface, screw terminal output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eATEX, IECEx, CSA, CE, RoHS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrimary Task\u003c\/td\u003e\n\u003ctd\u003eNon-contact vibration and shaft displacement measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eProximity Sensors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol and Channel-to-Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe CON021 converter conditions raw eddy-current impedance variations from the 16 mm PR6424\/013-030 probe, converting electromagnetic coil load changes into a standardized -4 VDC to -20 VDC output. Operating across a wide frequency bandwidth of 0 to 20 kHz with a response time faster than 15 us, the signal conditioning circuitry enables real-time dynamic tracking of high-velocity shaft motion. Dedicated channel-to-channel isolation prevents cross-talk and ground potential loops across multi-channel turbomachinery protection racks. High-level analog output signals route directly into process automation architectures for 4-20 mA HART loop protocol conversion, asset monitoring, and plant DCS diagnostic recording.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What power supply range is required to drive the CON021 converter loop?\u003c\/p\u003e\n\u003cp\u003eA: The CON021 converter requires a regulated negative DC power supply input between -23 VDC and -32 VDC.\u003c\/p\u003e\n\u003cp\u003eQ: What physical connectors are used on the CON021 converter housing?\u003c\/p\u003e\n\u003cp\u003eA: The unit features a LEMO connector interface for the sensor input side and screw terminals for the analog output and power supply connections.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProbe Threading and Clearance\u003c\/strong\u003e: Thread the M18 x 1.5 stainless steel probe body into the machine housing bracket. Ensure adequate radial clearance around the 16 mm tip to avoid metallic side-wall interference and measurement distortion.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding and Shielding\u003c\/strong\u003e: Connect the signal cabling shield strictly at a single point to functional earth at the monitoring cabinet terminal block to neutralize common-mode electrical noise.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCabinet Enclosure\u003c\/strong\u003e: Mount the IP20-rated CON021 signal converter using the M5 panel fixation points inside a sealed, NEMA\/IP-rated junction enclosure to protect the circuit board from dust and ambient humidity.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Emerson Epro","offers":[{"title":"Default Title","offer_id":45464109711475,"sku":"CON021+PR6424\/013-030","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/PR9376-010-011_3_4bedf4c3-a8ff-451e-9510-669718a4a67d.png?v=1788933477","url":"https:\/\/www.dcssupplier.com\/ar\/products\/epro-con021-pr6424-013-030-transducer-system","provider":"DcsSupplier Limited","version":"1.0","type":"link"}