{"product_id":"epro-con041-pr6424-006-131-eddy-current-measurement-system","title":"EPRO CON041+PR6424\/006-131 Eddy Current Measurement System","description":"\u003cp\u003eConfigured for high-speed shaft displacement and dynamic vibration monitoring, the \u003cstrong\u003eEmerson CON041+PR6424\/006-131\u003c\/strong\u003e (\u003cstrong\u003eCON041\u003c\/strong\u003e Signal Converter with \u003cstrong\u003ePR6424\u003c\/strong\u003e Eddy Current Sensor) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eOption \/ Suffix\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eConfiguration Parameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eValue \/ Feature Description\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCON041\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConverter Base Model\u003c\/td\u003e\n\u003ctd\u003eDIN-rail mounted signal converter for eddy current probes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePR6424\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSensor Base Model\u003c\/td\u003e\n\u003ctd\u003eNon-contact eddy current proximity sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\/006\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSensor Option Code\u003c\/td\u003e\n\u003ctd\u003e4 V\/mm (101.6 mV\/mil) sensitivity probe configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-131\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCable Option Code\u003c\/td\u003e\n\u003ctd\u003eArmored integral cable configuration with factory connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eCON041 + PR6424\/006-131\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEmerson EPRO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eSensor with 1 m cable: 200 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eNot specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eConverter: -30 to +100 deg C; Sensor: -35 to +180 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eConverter input: -23 VDC to -32 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Response\u003c\/td\u003e\n\u003ctd\u003e0 to 20,000 Hz (-3 dB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e-4 VDC to -20 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRise Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;15 us\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Range\u003c\/td\u003e\n\u003ctd\u003eStatic: +-2.0 mm; Dynamic: 0 to 1,000 um\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Sensitivity\u003c\/td\u003e\n\u003ctd\u003e4 V\/mm (101.6 mV\/mil) +-1.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock \/ Vibration Resistance\u003c\/td\u003e\n\u003ctd\u003e5g @ 60 Hz @ 25 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting \/ Protection\u003c\/td\u003e\n\u003ctd\u003eConverter: DIN rail \/ IP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE, ATEX, IECEx, CSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eSignal Converters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol and Channel-to-Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eThe CON041 converter processes high-frequency electromagnetic impedance variations from the PR6424\/006-131 probe into a proportional -4 VDC to -20 VDC output signal. Powered by a negative -23 VDC to -32 VDC supply, the circuit delivers a rapid rise time of less than 15 us to track dynamic vibration phenomena up to 20,000 Hz (-3 dB). Built-in channel-to-channel isolation prevents ground loop current leakage across multi-probe turbomachinery installations. Standard 4-20 mA HART loop protocol compatibility allows digital configuration, parameter polling, and diagnostic tracking when integrated with machinery protection and DCS networks.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What power supply voltage is required to operate the CON041 signal converter?\u003c\/p\u003e\n\u003cp\u003eA: The CON041 converter requires a regulated negative DC power supply operating within the range of -23 VDC to -32 VDC.\u003c\/p\u003e\n\u003cp\u003eQ: What is the output signal range of the CON041 converter when connected to the PR6424 probe?\u003c\/p\u003e\n\u003cp\u003eA: The converter generates a proportional negative DC output voltage ranging from -4 VDC to -20 VDC across the static measurement span of +-2.0 mm.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConverter DIN-Rail Mounting\u003c\/strong\u003e: Snap the IP20-rated CON041 converter securely onto a standard 35 mm DIN rail inside an IP54 or higher protective field enclosure to shield it from ambient dirt and moisture.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Probe Installation\u003c\/strong\u003e: Thread the PR6424 sensor into the rigid mounting fixture perpendicular to the shaft surface. Set the mechanical air gap using a feeler gauge or voltage meter to establish the zero-displacement reference point before locking the jam nut.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Shielding and Conduit\u003c\/strong\u003e: Route the sensor armored cable in dedicated grounded conduit separated from AC power lines and VFD conductors. Terminate signal shields at the designated converter grounding bus bar to ensure single-point earthing.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Emerson Epro","offers":[{"title":"Default Title","offer_id":45464117641331,"sku":"CON041+PR6424\/006-131","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/CON021_PR6423002-001-CN_2_0cba055c-382c-497c-b079-0464ee673a3c.jpg?v=1788932470","url":"https:\/\/www.dcssupplier.com\/ar\/products\/epro-con041-pr6424-006-131-eddy-current-measurement-system","provider":"DcsSupplier Limited","version":"1.0","type":"link"}