{"product_id":"epro-emerson-pr9268-617-100-velocity-sensor","title":"Epro Emerson PR9268\/617-100 Velocity Sensor","description":"\u003cp\u003eThe \u003cstrong\u003eEmerson PR9268\/617-100\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003ePR9268\u003c\/strong\u003e Electrodynamic Vibration Velocity Sensor, operates as a dedicated hardware component for continuous vibration velocity measurement within turbomachinery monitoring platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003ePR9268\/617-100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEpro \/ Emerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard body execution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +120 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive self-generating electrodynamic element\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring Range\u003c\/td\u003e\n\u003ctd\u003e0 to 1000 mm\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensitivity\u003c\/td\u003e\n\u003ctd\u003e28.5 mV\/mm\/s (723.9 mV\/in\/s) at 80 Hz, 20 deg C, 100 kOhm load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRepeatability\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.2% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Range\u003c\/td\u003e\n\u003ctd\u003e0.1 Hz to 10 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Response\u003c\/td\u003e\n\u003ctd\u003e10 Hz to 1 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Class\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHousing Material\u003c\/td\u003e\n\u003ctd\u003eStainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Material\u003c\/td\u003e\n\u003ctd\u003ePTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental Limits\u003c\/td\u003e\n\u003ctd\u003e0 to 100% Non-Condensing humidity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol \u0026amp; Channel Isolation\u003c\/h3\u003e\n\u003cp\u003eOutput signals generated by the passive electrodynamic coil module connect directly to system signal conditioners or 4-20 mA HART loop protocol transmitters. Incorporating channel-to-channel isolation within monitoring racks prevents common-mode noise corruption and eliminates ground loop currents across long-distance field cable runs.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the PR9268\/617-100 require an external power supply to output vibration signals? A: No, the sensor uses an electrodynamic seismic element that self-generates a proportional voltage signal relative to mechanical velocity.\u003c\/p\u003e\n\u003cp\u003eQ: What housing and cable construction materials are used to withstand harsh environments? A: The sensor body is constructed from stainless steel with an IP65 protection class, and it utilizes an integrated PTFE cable rated for continuous exposure from -40 to +120 deg C.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure a minimum of 5 full threads of engagement when securing mounting studs into the bearing casing port.\u003c\/li\u003e\n\u003cli\u003eRoute PTFE cable through grounded metal conduit away from high-voltage motor leads and variable frequency drive (VFD) output wiring to prevent noise interference.\u003c\/li\u003e\n\u003cli\u003eVerify that signal cable shielding is grounded at a single point (typically at the cabinet barrier or rack terminal) to prevent ground loops.\u003c\/li\u003e\n\u003cli\u003eMount the sensor strictly aligned along the required horizontal or vertical measurement axis before applying final mounting torque.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Emerson Epro","offers":[{"title":"Default Title","offer_id":45380803428467,"sku":"PR9268\/617-100","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/PR9268301-100_1_a1cec3ba-e4f9-4525-82de-3ccbb8c39d9d.png?v=1787279100","url":"https:\/\/www.dcssupplier.com\/ar\/products\/epro-emerson-pr9268-617-100-velocity-sensor","provider":"DcsSupplier Limited","version":"1.0","type":"link"}