{"product_id":"epro-pr6424-010-100-proximity-sensor-module","title":"EPRO PR6424\/010-100 Proximity Sensor Module","description":"\u003cp\u003eConfigured for shaft vibration and relative displacement monitoring in rotating machinery monitoring systems, the \u003cstrong\u003eEPRO PR6424\/010-100\u003c\/strong\u003e (\u003cstrong\u003ePR6424\u003c\/strong\u003e Proximity Sensor Module) provides direct physical execution.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBase Model (PR6424)\u003c\/strong\u003e: Non-contact eddy-current proximity probe series designed for static and dynamic shaft displacement measurements.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuffix (\/010-100)\u003c\/strong\u003e: Specifies the internal body execution, thread mounting configuration, integrated cable length, and connector termination arrangement.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003ePR6424\/010-100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEPRO \/ Emerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eGermany\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 0.30 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eThreaded cylindrical body (Standard length)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-35 to +180 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive probe element (Driven by signal converter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Type\u003c\/td\u003e\n\u003ctd\u003eEddy-current proximity sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTarget Material\u003c\/td\u003e\n\u003ctd\u003eFerromagnetic steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Interface\u003c\/td\u003e\n\u003ctd\u003eRaw high-frequency RF output to signal converter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation \u0026amp; Signal Conditioning\u003c\/h3\u003e\n\u003cp\u003eWhen integrated into process control systems, raw eddy-current signals from the probe pass through dedicated signal converters to deliver standardized process outputs. Incorporating channel-to-channel isolation within the measurement loop prevents ground loops and eliminates noise pickup across long distance cable runs in high-density DCS instrumentation cabinets.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the PR6424\/010-100 probe require direct DC supply voltage at the terminal connections?\u003c\/p\u003e\n\u003cp\u003eA: No, the passive probe element receives high-frequency excitation voltage directly from its associated signal converter module rather than an external DC power supply.\u003c\/p\u003e\n\u003cp\u003eQ: How is the physical measurement range adjusted during field installation?\u003c\/p\u003e\n\u003cp\u003eA: Measurement range center-point setting requires measuring the DC gap voltage at the converter output terminals to establish correct nominal mechanical clearance from the shaft surface.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eEnsure a minimum of 5 full threads of engagement when mounting the sensor into tapped machine casing ports.\u003c\/li\u003e\n\u003cli\u003eRoute extension cabling through grounded metal conduit, isolated from high-voltage motor conductors and variable frequency drive (VFD) power wiring.\u003c\/li\u003e\n\u003cli\u003eVerify that signal cable shielding terminates at a single grounding point, typically at the monitor rack cabinet barrier, to prevent ground loop currents.\u003c\/li\u003e\n\u003cli\u003eConfirm mechanical clearance across 360 degrees of shaft rotation using a feeler gauge prior to applying power to the signal conditioning unit.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Emerson Epro","offers":[{"title":"Default Title","offer_id":45380815519859,"sku":"PR6424\/010-100","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/PR9376-010-011_3_9278d2d8-86ce-421c-aba2-1e1ce857e056.png?v=1787278959","url":"https:\/\/www.dcssupplier.com\/ar\/products\/epro-pr6424-010-100-proximity-sensor-module","provider":"DcsSupplier Limited","version":"1.0","type":"link"}