{"product_id":"epro-pr6480-041-000-current-signal-converter","title":"EPRO PR6480\/041-000 Current Signal Converter","description":"\u003cp\u003eThe \u003cstrong\u003eEmerson PR6480\/041-000\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003ePR6480\u003c\/strong\u003e Eddy Current Signal Converter, operates as a dedicated hardware component for radial and axial shaft displacement, position, eccentricity, and speed measurement within MMS6000 protection platforms. The converter processes dynamic eddy-current probe voltage inputs to generate proportional electrical telemetry across a frequency bandwidth of 0 to 20000 Hz.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eSuffix Component\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eTechnical Feature \u0026amp; Option Designation\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePR6480\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBase Series for Non-Contacting Eddy Current Signal Converter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\/041\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSpecific Circuit Configuration \u0026amp; Sensor Chain Calibration Scaling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e-000\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard Cable Termination \u0026amp; Unarmored Base Hardware Option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003ePR6480\/041-000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEmerson \/ Epro\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eGERMANY\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.40 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e128 mm x 22.5 mm x 114.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-10 deg C to +50 deg C (Converter)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e4.5 W at 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDynamic Frequency Range\u003c\/td\u003e\n\u003ctd\u003e0 to 20000 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp Range\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Humidity\u003c\/td\u003e\n\u003ctd\u003e10% to 90% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAtmospheric Pressure\u003c\/td\u003e\n\u003ctd\u003e86 to 106 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Tip Material\u003c\/td\u003e\n\u003ctd\u003eEpoxy Resin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCase Material\u003c\/td\u003e\n\u003ctd\u003eStainless Steel with EPDM O-Ring Sealing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Material\u003c\/td\u003e\n\u003ctd\u003ePolyolefine\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor \u0026amp; 1m Cable Temp\u003c\/td\u003e\n\u003ctd\u003e-35 deg C to +80 deg C (-31 deg F to +176 deg F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRadiation Resistance\u003c\/td\u003e\n\u003ctd\u003eSensor \u0026amp; 1m cable: up to 80 Mrad; Cable \u0026amp; converter: up to 0.1 Mrad\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e4-20 mA HART Loop Protocol and DCS Connectivity\u003c\/h3\u003e\n\u003cp\u003eThe PR6480\/041-000 converts raw proximity transducer signals into standardized output levels for 4-20 mA HART loop protocol architectures and DCS networks. Built-in channel-to-channel isolation eliminates ground potential offset errors between field sensor probes and centralized processing racks. Active cold junction compensation (CJC) logic and active temperature stabilization maintain signal linearity across varying environmental conditions (-35 deg C to +80 deg C for field-mounted sensors). Direct signal output compatibility with Emerson Ovation and DeltaV platforms enables low-latency delivery of radial displacement and dynamic vibration parameters.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What are the distinct radiation tolerance thresholds for the sensor probe versus the signal converter?\u003c\/p\u003e\n\u003cp\u003eA: The epoxy resin sensor tip and integrated 1 m cable withstand cumulative radiation exposure up to 80 Mrad, whereas the extension cable and signal converter housing are rated up to 0.1 Mrad.\u003c\/p\u003e\n\u003cp\u003eQ: How does the stainless steel housing construction maintain sealing under industrial ambient conditions?\u003c\/p\u003e\n\u003cp\u003eA: The converter case features stainless steel construction fitted with EPDM O-ring sealing, preventing ingress under atmospheric operating pressures ranging from 86 to 106 kPa and non-condensing relative humidity between 10% and 90%.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eSecure the signal converter inside a protective NEMA\/IP enclosure maintained within the allowable operating temperature window (-10 deg C to +50 deg C).\u003c\/li\u003e\n\u003cli\u003eDirect all polyolefine sensor cabling through grounded metallic flexible conduits to isolate high-frequency signals from adjacent power wiring.\u003c\/li\u003e\n\u003cli\u003eTerminate cable drain shields exclusively at the designated cabinet instrument ground bus (single-point grounding) to prevent stray ground loops.\u003c\/li\u003e\n\u003cli\u003eVerify that the EPDM O-ring seal on the stainless steel case body is properly seated prior to field mounting to ensure environmental isolation.\u003c\/li\u003e\n\u003cli\u003eTorque threaded connector fittings according to standard field cabinet installation specifications to maintain mechanical stability and seal tightness.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Emerson Epro","offers":[{"title":"Default Title","offer_id":45499123826803,"sku":"PR6480\/041-000","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/CON021_PR6423002-001-CN_1_7196584f-b8d8-4c2d-99c9-1ce7411b3441.jpg?v=1789453680","url":"https:\/\/www.dcssupplier.com\/ar\/products\/epro-pr6480-041-000-current-signal-converter","provider":"DcsSupplier Limited","version":"1.0","type":"link"}