{"product_id":"ge-4136j53-g01-press-limiter-board","title":"GE 4136J53-G01 Press Limiter Board","description":"\u003cp\u003eThe \u003cstrong\u003eGE 4136J53-G01\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eGE4136J53-G01\u003c\/strong\u003e Press Limiter Board, operates as a dedicated hardware component for real-time tonnage monitoring and machinery overload limit execution within industrial stamping press control platforms. It converts strain gauge analog inputs into continuous load feedback to trip safety relays when press tonnage thresholds exceed configured limits.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eGE4136J53-G01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eCircuit Board Assemblies\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Inputs\u003c\/td\u003e\n\u003ctd\u003e2 strain gauge channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSetpoint Range\u003c\/td\u003e\n\u003ctd\u003e0 to 100% of press capacity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e5 ms typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Relays\u003c\/td\u003e\n\u003ctd\u003e2 Form-C relays\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelay Contact Rating\u003c\/td\u003e\n\u003ctd\u003e5 A at 240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTrip Accuracy\u003c\/td\u003e\n\u003ctd\u003e2% of setpoint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHysteresis\u003c\/td\u003e\n\u003ctd\u003eAdjustable 2 to 10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e195 mm x 25 mm x 150 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.38 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e115 VAC or 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Dissipation\u003c\/td\u003e\n\u003ctd\u003e4 W maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication and Deterministic Logic Execution\u003c\/h3\u003e\n\u003cp\u003eThe board leverages high backplane bus communication velocity and direct analog hardware comparison loops to maintain a 5 ms typical trip response time. High component density scaling integrates two independent strain gauge channels alongside Form-C output relays, suppressing switching noise across sensitive millivolt signal traces. Onboard firmware flash compatibility ensures synchronized cyclic scan execution with primary press control systems to enforce real-time peak load limits.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What input signal cabling is required for the strain gauge measurement channels on the GE4136J53-G01?\u003c\/p\u003e\n\u003cp\u003eA: Field connections to the two strain gauge channels must utilize shielded twisted-pair cabling to prevent electromagnetic noise coupling from heavy drive motor cabling.\u003c\/p\u003e\n\u003cp\u003eQ: How does the output relay reset function after a tonnage overload trip condition is cleared?\u003c\/p\u003e\n\u003cp\u003eA: The board requires a manual reset input signal after peak tonnage drops back below the configured hysteresis threshold to re-enable normal press operation.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eDe-energize all primary 115 VAC or 24 VDC power sources to the press control panel and isolate line voltage feeds before installation.\u003c\/li\u003e\n\u003cli\u003eMount the board securely within the control cabinet, ensuring all mounting standoffs maintain electrical ground bond with the panel backplate.\u003c\/li\u003e\n\u003cli\u003eWire the strain gauge sensors using shielded twisted-pair cables, grounding the cable shield at the cabinet entry gland only.\u003c\/li\u003e\n\u003cli\u003eConnect the two Form-C output relay contacts directly into the press emergency stop safety loop.\u003c\/li\u003e\n\u003cli\u003eApply power and adjust the onboard potentiometers to calibrate setpoint range (0 to 100%) and hysteresis levels (2 to 10%) per press machine ratings.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":66727577878643,"sku":"4136J53-G01","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/4136J58-G012_Cocoai_60483ba6-7199-4840-b6d5-ce04233382db.jpg?v=1790565835","url":"https:\/\/www.dcssupplier.com\/ar\/products\/ge-4136j53-g01-press-limiter-board","provider":"DcsSupplier Limited","version":"1.0","type":"link"}