{"product_id":"ge-4136j63-g01-position-monitoring-cards","title":"GE 4136J63-G01 Position Monitoring Cards","description":"\u003cp\u003eThe \u003cstrong\u003eGE 4136J63-G01\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e4136J63\u003c\/strong\u003e Thrust Wear Board \/ Position Monitor, operates as a dedicated hardware component for axial position monitoring and LVDT signal conditioning within GE turbine control platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e4136J63-G01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE (General Electric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.37 kg (370 grams)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e190 mm x 150 mm x 25 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePower supply noise filtered via 1320 uF energy bank\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Range\u003c\/td\u003e\n\u003ctd\u003e0 to 2.5 mm axial displacement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Interface\u003c\/td\u003e\n\u003ctd\u003e2-channel differential (LVDT compatible)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal\u003c\/td\u003e\n\u003ctd\u003e0-10 VDC analog (linearized)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Output\u003c\/td\u003e\n\u003ctd\u003e2 relay contacts (warning + danger)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e+\/-0.5% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Response\u003c\/td\u003e\n\u003ctd\u003eDC to 100 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity and Firmware Integration\u003c\/h3\u003e\n\u003cp\u003eThe GE 4136J63-G01 utilizes a 136-component signal conditioning array to maintain high backplane bus communication velocity and real-time analog data transmission. Non-volatile register configuration provides full firmware flash compatibility across attached control racks, allowing the board to process 0-10 VDC linearized position outputs without scan cycle degradation. The internal differential amplifiers reject common-mode noise over extended cable lengths, guaranteeing deterministic signal updates to system logic.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the primary function of the onboard 1320 uF capacitor energy storage bank?\u003c\/p\u003e\n\u003cp\u003eA: The four 330 uF capacitors (1320 uF total) act as a dedicated power supply ripple filter to stabilize voltage rails for high-precision LVDT signal conditioning circuits and eliminate electrical noise.\u003c\/p\u003e\n\u003cp\u003eQ: How are the warning and trip relay thresholds configured on the 4136J63-G01 module?\u003c\/p\u003e\n\u003cp\u003eA: The board includes two independent relay channels hardwired for protection logic; the warning relay engages at 1.5 mm of axial displacement, while the danger trip relay actuates at 2.0 mm to trigger system shutdown.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003ePower De-energization: Isolate all incoming primary supply power and relay contact loop voltages prior to mounting or servicing the circuit board within the enclosure chassis.\u003c\/li\u003e\n\u003cli\u003ePanel Mounting: Secure the board vertically to the enclosure backplate using four M4 mounting screws through the pre-drilled chassis mounting holes.\u003c\/li\u003e\n\u003cli\u003eLVDT Wiring Limits: Route dual-channel LVDT inputs using shielded twisted-pair (STP) wiring up to a maximum run distance of 100 meters to ensure accurate differential noise rejection.\u003c\/li\u003e\n\u003cli\u003eShield Grounding: Connect all incoming signal cable drain wires directly to the functional earth (FE) bus bar at the panel entrance to prevent electromagnetic interference from distorting axial position measurements.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":45473790525555,"sku":"4136J63-G01","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/874E136-G06_2__Cocoai_626b19dc-a0fe-45fd-aff6-aabcbda49a1e.jpg?v=1789099008","url":"https:\/\/www.dcssupplier.com\/ar\/products\/ge-4136j63-g01-position-monitoring-cards","provider":"DcsSupplier Limited","version":"1.0","type":"link"}