{"product_id":"ge-8164-4002-output-module","title":"GE 8164-4002 Output Module","description":"\u003cp\u003eThe \u003cstrong\u003eGE 8164-4002\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e8164-4002\u003c\/strong\u003e Output Module, operates as a dedicated hardware component for discrete load switching within GEM 80 PLC platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e8164-4002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnited Kingdom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.53 kg (1.17 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e29 mm x 235 mm x 235 mm (2.9 cm x 23.5 cm x 23.5 cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eStandard backplane power allocation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003e32-way discrete DC output module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current Rating\u003c\/td\u003e\n\u003ctd\u003e0.5 A per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity and I\/O Density Scaling\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Bus Communication Velocity\u003c\/strong\u003e: Synchronizes output bit patterns across the GEM 80 backplane bus to ensure real-time command processing with minimal scan overhead.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/O Density Scaling\u003c\/strong\u003e: Integrates 32 independent output switching channels into a single card slot to optimize space utilization inside control subracks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFirmware Flash Compatibility\u003c\/strong\u003e: Maintains full electrical compatibility with GEM 80 central processing units and system chassis backplanes.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the maximum continuous current rating per output channel on the 8164-4002 module?\u003c\/p\u003e\n\u003cp\u003eA: Each of the 32 discrete channels is rated to drive up to 0.5 A continuous current at 24 VDC nominal operating voltage.\u003c\/p\u003e\n\u003cp\u003eQ: How does the module interface physically with the GEM 80 chassis?\u003c\/p\u003e\n\u003cp\u003eA: The card slides into standard subrack guides (occupying 2.9 cm width) and connects directly to the system backplane via its rear connector assembly.\u003c\/p\u003e\n\u003cp\u003eQ: Are there specific installation precautions when connecting inductive loads to the module outputs?\u003c\/p\u003e\n\u003cp\u003eA: Yes, external flywheel or surge suppression diodes must be wired directly across inductive DC loads to clamp voltage transients and protect the output switching circuitry.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Insertion\u003c\/strong\u003e: Slide the circuit card assembly smoothly into the designated GEM 80 subrack slot along the guide rails until fully seated in the backplane connector.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Termination\u003c\/strong\u003e: Terminate field cables at the designated terminal block or connector system, verifying correct 24 VDC polarity and current limits per terminal.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding and Grounding\u003c\/strong\u003e: Ensure the subrack chassis is bonded to the main enclosure earth ground bar via a low-impedance ground conductor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Separation\u003c\/strong\u003e: Route 24 VDC output signal conductors in separate cable ducts away from high-voltage AC lines to prevent induced electrical noise.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":45328695165043,"sku":"8164-4002","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/8164-4002_1200x1200_4ea1e927-6c87-4aa8-8995-c414890917db.jpg?v=1786082488","url":"https:\/\/www.dcssupplier.com\/ar\/products\/ge-8164-4002-output-module","provider":"DcsSupplier Limited","version":"1.0","type":"link"}