{"product_id":"ge-a06b-6076-h105-robot-servo-amplifier-module","title":"GE A06B-6076-H105 Robot Servo Amplifier Module","description":"\u003cp\u003eThe \u003cstrong\u003eGE Fanuc A06B-6076-H105\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eA06B-6076-H105\u003c\/strong\u003e Servo Amplifier Modules, operates as a dedicated hardware component for multi-axis motor current loop arbitration and motion execution within GE Fanuc C-Series robot controller platforms. Interfacing directly with a 200–230 VAC supply, this 6-axis open-frame servo drive delivers pulse-width modulated current to drive 6 articulated robot joint motors up to a 5.5 kW power threshold.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eA06B-6076-H105\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e31.75 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard C-Series 6-axis open-frame drive footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e5.5 kW total output power capacity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage\u003c\/td\u003e\n\u003ctd\u003e200–230 VAC, 3-Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAxis Count\u003c\/td\u003e\n\u003ctd\u003e6-Axis control capability\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChassis Type\u003c\/td\u003e\n\u003ctd\u003eOpen Frame\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDeterministic Drive \u0026amp; Backplane Execution\u003c\/h3\u003e\n\u003cp\u003eThe multi-axis servo amplifier coordinates high-speed PWM switching and encoder feedback loops across all six articulated joint axes simultaneously. Integrating directly with the controller backplane, the unit maintains firmware flash compatibility while processing real-time trajectory commands over Profinet \/ EtherNet\/IP deterministic networks. High backplane bus communication velocity guarantees synchronized multi-axis position feedback and instant torque limit response under dynamic robot payloads.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can individual axis cables be plugged in or removed while the 200–230 VAC line power is energized?\u003c\/p\u003e\n\u003cp\u003eA: No. Plugging or unplugging servo motor power lines or feedback cables while power is applied can induce severe electrical arcing, damaging output IGBT modules and corrupting position encoder logic circuits. Always disconnect main controller power before servicing.\u003c\/p\u003e\n\u003cp\u003eQ: What precautions should be taken regarding the open-frame chassis construction?\u003c\/p\u003e\n\u003cp\u003eA: Because the unit features an open-frame layout, it relies entirely on the host robot controller cabinet to maintain ingress protection. Ensure the main panel enclosure remains sealed to prevent conductive dust, oil mist, or moisture from settling on exposed power circuits.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Disconnection:\u003c\/strong\u003e Shut off the main circuit breaker supplying the robot controller. Wait at least 5 minutes for internal high-voltage DC bus capacitors to discharge below 50 VDC before opening access doors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Mounting:\u003c\/strong\u003e Secure the open-frame amplifier vertically onto the panel mounting plate using all primary mounting holes to ensure structural rigidity and proper grounding contact.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding \u0026amp; Shielding:\u003c\/strong\u003e Connect the drive frame chassis ground lug directly to the central panel earth bus bar. Route feedback encoder lines using 360-degree shielded cables grounded at the enclosure entrance point.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Isolation:\u003c\/strong\u003e Route 3-phase AC input lines and motor output cables in separate wiring ducts away from low-voltage DC communication and safety stop circuits to prevent electromagnetic interference (EMI).\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":45464540807283,"sku":"A06B-6076-H105","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/A06B-6076-H105_6dbec71f-f320-4c81-9264-9ecb8f0e89c2.png?v=1788938333","url":"https:\/\/www.dcssupplier.com\/ar\/products\/ge-a06b-6076-h105-robot-servo-amplifier-module","provider":"DcsSupplier Limited","version":"1.0","type":"link"}