{"product_id":"ge-a370-8024-0013-servo-module","title":"GE A370-8024-0013 Servo Module","description":"\u003cp\u003eConfigured for motion control execution in industrial control systems, the \u003cstrong\u003eGE A370-8024-0013\u003c\/strong\u003e (\u003cstrong\u003eA370-8024\u003c\/strong\u003e Servo Module) provides direct physical\/electrical execution. It drives 2 axes of motion simultaneously or independently, executing velocity and position algorithms via an onboard 16-bit DSP operating at 25 MHz. The card processes incremental encoder feedback over dual RS-422 channels and generates ±10V analog torque commands to drive external servo amplifiers directly.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eA370-8024-0013\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE (General Electric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA \/ Assembled in USA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e820 grams\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e310 mm x 200 mm x 35 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive backplane logic draw (Onboard energy storage: 5440 uF total)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCategory\u003c\/td\u003e\n\u003ctd\u003eServo Module \/ Motion Controller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControlled Axes\u003c\/td\u003e\n\u003ctd\u003e2 axes (simultaneous or independent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor\u003c\/td\u003e\n\u003ctd\u003e16-bit DSP at 25 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFeedback Input\u003c\/td\u003e\n\u003ctd\u003e2 channels for incremental encoders (RS-422)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal\u003c\/td\u003e\n\u003ctd\u003e+\/-10V analog torque command\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Interface\u003c\/td\u003e\n\u003ctd\u003e2 x 50-pin ribbon connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnergy Storage\u003c\/td\u003e\n\u003ctd\u003e8 x 680 uF capacitors (5440 uF total)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eComponent Count\u003c\/td\u003e\n\u003ctd\u003e234 discrete components\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity \u0026amp; Firmware Flash Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE A370-8024-0013\u003c\/strong\u003e motion controller synchronizes axis calculations with host CPU cycles to maintain backplane bus communication velocity across card cage backplanes. The integrated 16-bit DSP at 25 MHz maintains firmware flash compatibility, allowing high-speed motion profile execution and dual-axis gantry coordination without introducing processing latency. Onboard energy storage consisting of eight 680 uF capacitors (5440 uF total) buffers peak current demands during acceleration ramps, preventing backplane supply voltage dips during high-load servo cycles.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the two controlled axes on the A370-8024-0013 be operated independently?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes. The module allows the two axes to be configured either for coordinated gantry moves or for completely independent axis control.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What type of encoder feedback interface is supported by the card?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The board incorporates 2 feedback channels designed specifically for incremental encoders using RS-422 differential signal standards.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Are external signal conditioning cards required to connect the module to standard servo drives?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e No. The module generates direct ±10V analog torque output commands that interface directly with external servo drive amplifiers via a 50-pin ribbon cable.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Disconnection\u003c\/strong\u003e: Turn off system rack power before inserting or removing the card to prevent damage to edge connectors and onboard capacitors.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCard Insertion\u003c\/strong\u003e: Align the 310 mm x 200 mm card with the enclosure card guides. Slide the module into the slot and press the two metal ejector handles inward until the backplane connectors seat fully.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRibbon Cable Termination\u003c\/strong\u003e: Secure the 2 x 50-pin ribbon cables to the front panel interface connectors, verifying latch locking to prevent signal disconnection during machine vibration.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielded Wiring\u003c\/strong\u003e: Route RS-422 encoder feedback lines and ±10V analog command cables in separate grounded metal conduits away from high-voltage AC motor power leads.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrame Grounding\u003c\/strong\u003e: Ensure the card cage chassis is grounded to the panel earth bus. Verify that the metal ejector assembly makes metal-to-metal contact with the grounded rack frame.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp\u003ees are transferred across the 64-pin DIN 41612 backplane interface to host controllers, drawing 320 mA from the 5 VDC logic bus.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC697MDL250F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e450 grams\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e275 x 190 x 22 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eStandard Industrial Limits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e320 mA at 5 VDC logic supply; 35 mA idle \/ 259 mA full load at 24 VDC field supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Inputs\u003c\/td\u003e\n\u003ctd\u003e32 sinking channels (2 isolation groups of 16 channels)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Field Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC (10 to 30 VDC input range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current\u003c\/td\u003e\n\u003ctd\u003e7 mA per channel at 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogic High Threshold\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 15 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogic Low Threshold\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e1 ms typical turn-on \/ turn-off delay\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSelectable Input Filter\u003c\/td\u003e\n\u003ctd\u003e1 ms or 10 ms (configurable via onboard DIP switch)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Voltage\u003c\/td\u003e\n\u003ctd\u003e1,500 V RMS (group-to-logic isolation)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReverse Polarity Protection\u003c\/td\u003e\n\u003ctd\u003eYes (continuous)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Indicators\u003c\/td\u003e\n\u003ctd\u003e32 green channel LEDs, 1 green power LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOnboard Filtering \/ Energy\u003c\/td\u003e\n\u003ctd\u003e4 x 47 uF capacitors (0.04 Joules total stored energy)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBoard Component Count\u003c\/td\u003e\n\u003ctd\u003e198 total components\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectors\u003c\/td\u003e\n\u003ctd\u003e64-pin DIN 41612 backplane connector, 48-pin front field connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity \u0026amp; Network Integration\u003c\/h3\u003e\n\u003cp\u003eThe IC697MDL250F maintains backplane bus communication velocity by performing onboard signal debounce and configurable input filtering (1 ms or 10 ms via hardware DIP switches) prior to driving logic state data across the backplane bus. The 64-pin DIN 41612 connector provides high-integrity backplane bus signaling, while onboard power decoupling via four 47 uF electrolytic capacitors buffers internal voltage rails against field-induced power noise. Dedicated channel optocouplers deliver 1,500 V RMS isolation between external field wiring and internal bus logic tracks, ensuring firmware flash compatibility and logic execution stability across all Series 90-70 racks.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What are the logic threshold levels and field power requirements for signal detection?\u003c\/p\u003e\n\u003cp\u003eA: The input channels require a 24 VDC field supply (drawing 35 mA at idle and up to 259 mA with all 32 channels active at 7 mA per point). Logic high is detected at voltages above 15 VDC, while logic low is triggered below 5 VDC.\u003c\/p\u003e\n\u003cp\u003eQ: How is input channel filtering adjusted on the module circuit board?\u003c\/p\u003e\n\u003cp\u003eA: Signal delay times can be set to either 1 ms or 10 ms using onboard hardware DIP switches located directly on the module card assembly.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003ePower off the target Series 90-70 rack chassis before inserting or extracting the input card.\u003c\/li\u003e\n\u003cli\u003eAlign card edges with the designated rack slot guides and slide the module back until the 64-pin DIN 41612 backplane connector fully seats into the chassis receptacle.\u003c\/li\u003e\n\u003cli\u003eFasten top and bottom panel retention screws to maintain chassis ground grounding and lock the module against mechanical vibration.\u003c\/li\u003e\n\u003cli\u003eWire 24 VDC external field power and sinking input points to the 48-pin front field connector block, maintaining separation from high-voltage AC cables inside wiring troughs.\u003c\/li\u003e\n\u003cli\u003eConfirm correct field power supply polarity before energizing the 24 VDC loop circuit; internal continuous reverse polarity protection shields module hardware in the event of miswiring.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":45434640466035,"sku":"A370-8024-0013","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/GE-A370-8024-0013_1200x1200_a92741f8-03b3-4810-9144-c0a8d78996ad.jpg?v=1788314660","url":"https:\/\/www.dcssupplier.com\/ar\/products\/ge-a370-8024-0013-servo-module","provider":"DcsSupplier Limited","version":"1.0","type":"link"}