{"product_id":"ge-a61l-0001-0093-lcd-displays","title":"GE A61L-0001-0093 LCD Displays","description":"\u003cp\u003eThe \u003cstrong\u003eGE Fanuc A61L-0001-0093\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eA61L-0001-0093\u003c\/strong\u003e LCD Display, operates as a dedicated hardware component for visual feedback and operator telemetry execution within GE Fanuc control systems. Configured for visual status output and industrial control interfacing, the module provides direct physical\/electrical execution. It interfaces directly with central processing logic to render real-time diagnostics, machine positioning, and graphical system parameters across connected operator stations.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eA61L-0001-0093\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA \/ Assembled in USA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eTotal Shipping Weight: 8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eIndustrial panel mount footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eDC 24V \/ 0.3A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eLCD Display\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Current\u003c\/td\u003e\n\u003ctd\u003e0.3 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity \u0026amp; Firmware Flash Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe \u003cstrong\u003eGE Fanuc A61L-0001-0093\u003c\/strong\u003e display unit processes video telemetry data over high-speed hardware interfaces to match backplane bus communication velocity across host CNC and PLC systems. Built-in signal conditioning logic processes display updates synchronously with backplane logic cycles without introducing frame delay. Preloaded firmware flash compatibility ensures uniform instruction execution and parameter synchronization, maintaining display stability and video rendering accuracy during high-volume data polling sweeps.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What are the input electrical power requirements for the A61L-0001-0093 LCD unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The display operates on a direct current supply requirement of 24 VDC at a current draw of 0.3 A.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the A61L-0001-0093 display module be replaced without removing system control power?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e No. Control system power must be disconnected prior to mounting or disconnecting the display unit to avoid DC power surges and signal terminal damage.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the total shipping weight of the unit for panel structural mounting consideration?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The total shipping weight of the unit and its immediate enclosure structure is 8 kg.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Isolation\u003c\/strong\u003e: Disconnect input 24 VDC power to the display subsystem panel before commencing mounting or electrical termination steps.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePanel Cutout Mounting\u003c\/strong\u003e: Position the A61L-0001-0093 display module into the designated enclosure cutout. Secure all panel mounting brackets evenly to ensure a flush seal against dust and contaminants.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDC Wiring Connection\u003c\/strong\u003e: Connect the 24 VDC power leads to the designated power terminal block, verifying correct polarity (+24V and 0V) prior to energizing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSignal Cable Engagement\u003c\/strong\u003e: Attach the video signal interface cable to the rear connector, tightening any mechanical locking screws to ensure vibration-proof signal contact.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFrame Grounding\u003c\/strong\u003e: Run a low-impedance ground wire from the chassis ground terminal to the enclosure cabinet ground bar to prevent static build-up and electrical interference.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":45434639941747,"sku":"A61L-0001-0093","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/A61L-0001-0093.png?v=1788314662","url":"https:\/\/www.dcssupplier.com\/ar\/products\/ge-a61l-0001-0093-lcd-displays","provider":"DcsSupplier Limited","version":"1.0","type":"link"}