{"product_id":"ge-fanuc-a03b-0819-c182-aod16dp-digital-i-o-module","title":"GE Fanuc A03B-0819-C182 AOD16DP Digital I\/O Module","description":"\u003cp\u003eConfigured for discrete signal output execution in GE Fanuc CNC and PLC systems, the \u003cstrong\u003eGE Fanuc A03B-0819-C182\u003c\/strong\u003e (\u003cstrong\u003eA03B-0819-C182\u003c\/strong\u003e Digital I\/O Module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eA03B-0819-C182 (AOD16DP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.85 kg (1.87 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Fanuc I\/O unit footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eStandard system backplane power allocation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eDiscrete DC output module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Points\u003c\/td\u003e\n\u003ctd\u003e16 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Type\u003c\/td\u003e\n\u003ctd\u003e24 VDC digital output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity and I\/O Density Scaling\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Bus Communication Velocity\u003c\/strong\u003e: Transfers high-speed discrete state signals over the internal system bus, ensuring deterministic updating between control processing units and field actuators.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eI\/O Density Scaling\u003c\/strong\u003e: Integrates 16 dedicated DC output channels into a compact physical housing, optimizing rack space and simplifying field termination for solenoid and relay control circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFirmware Flash Compatibility\u003c\/strong\u003e: Maintains full electrical and protocol continuity across compatible GE Fanuc CNC\/PLC hardware architectures, guaranteeing direct drop-in replacement functionality.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the channel capacity of the A03B-0819-C182 digital output module?\u003c\/p\u003e\n\u003cp\u003eA: The module provides 16 discrete DC output points (AOD16DP) designed for driving field loads such as relays, indicators, and small solenoids.\u003c\/p\u003e\n\u003cp\u003eQ: How does the module interface with the main control system backplane?\u003c\/p\u003e\n\u003cp\u003eA: The module mounts onto the standard rack or backplane base, establishing direct backplane communication for logic state updates and power distribution.\u003c\/p\u003e\n\u003cp\u003eQ: Are special firmware adjustments needed when replacing an existing AOD16DP module?\u003c\/p\u003e\n\u003cp\u003eA: No, the hardware maintains full bus and protocol compatibility, enabling straightforward field replacement without modifying CPU system software.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePhysical Mounting\u003c\/strong\u003e: Align the module edge connector with the backplane slot, pressing firmly to lock the card retainers into place.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Termination\u003c\/strong\u003e: Connect 24 VDC output field lines using standard terminal blocks or connector plugs, adhering to pinout diagrams provided in control cabinet schematics.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding Practice\u003c\/strong\u003e: Ensure the rack chassis is bonded to cabinet earth ground with a short, low-impedance grounding conductor to prevent electrical interference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Separation\u003c\/strong\u003e: Route DC output signal cables separately from high-voltage AC mains and motor power lines inside cabinet ducting to prevent capacitive coupling.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":45328694771827,"sku":"A03B-0819-C182","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/A03B-0819-C182_1200x1200_1aa10cfa-a081-447f-9339-92bb4aa12e29.jpg?v=1786082498","url":"https:\/\/www.dcssupplier.com\/ar\/products\/ge-fanuc-a03b-0819-c182-aod16dp-digital-i-o-module","provider":"DcsSupplier Limited","version":"1.0","type":"link"}