{"product_id":"ge-fanuc-ic660ebd110-genius-i-o-electronics-assembly","title":"GE Fanuc IC660EBD110 Genius I\/O Electronics Assembly","description":"\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC660EBD110\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIC660BBD110\u003c\/strong\u003e Electronics Assembly, operates as a dedicated hardware component for discrete AC input voltage sensing and signal isolation within Genius I\/O bus networks.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC660EBD110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc \/ Emerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Line\u003c\/td\u003e\n\u003ctd\u003eGenius I\/O Block\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eDiscrete Input Electronics Assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Complete Block\u003c\/td\u003e\n\u003ctd\u003eIC660BBD110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Terminal Base\u003c\/td\u003e\n\u003ctd\u003eIC660TBD110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Inputs\u003c\/td\u003e\n\u003ctd\u003e16 Discrete AC Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Input Voltage\u003c\/td\u003e\n\u003ctd\u003e115 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e93 to 132 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Range\u003c\/td\u003e\n\u003ctd\u003e47 to 63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDevice Current\u003c\/td\u003e\n\u003ctd\u003e80 mA Max Block Current \/ 200 mA Circuit Current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeat Dissipation\u003c\/td\u003e\n\u003ctd\u003e28 W Max (All 16 Inputs ON at Full Current)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation Rating\u003c\/td\u003e\n\u003ctd\u003e1500 V Input to Ground \/ Serial Bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Resistance\u003c\/td\u003e\n\u003ctd\u003e11.6 kohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to 100 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95 percent Non-Condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e8.83 x 3.50 x 3.94 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e4.00 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUnspecified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity \u0026amp; Deterministic Network Execution\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBackplane Bus Communication Velocity:\u003c\/strong\u003e The assembly interfaces directly with the Genius serial bus via the terminal base, transferring discrete input state bit maps to the CPU controller with typical channel processing latencies of 1 ms plus configured filter delays (10 to 100 ms).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDiagnostic Report \u0026amp; State Execution:\u003c\/strong\u003e Integrated voltage-sensing networks detect open-wire and shorted-wire conditions per channel, transmitting diagnostic fault packets over the Genius bus while driving local status LEDs (Unit OK, I\/O Enabled, and 16 channel LEDs).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFirmware \u0026amp; Hardware Compatibility:\u003c\/strong\u003e Designed for mounting on the IC660TBD110 terminal base, onboard logic maintains memory alignment across Genius I\/O bus controllers without requiring firmware flashing during assembly replacement.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the IC660EBD110 electronics assembly be installed or removed while the terminal base is energized?\u003c\/p\u003e\n\u003cp\u003eA: No. The IC660EBD110 does not support Removal and Insertion Under Power (RIUP). Main supply power to the terminal base must be completely disconnected before inserting or disengaging the assembly to avoid board damage or corrupted serial bus communications.\u003c\/p\u003e\n\u003cp\u003eQ: What is the isolation capability between field input circuits and ground logic?\u003c\/p\u003e\n\u003cp\u003eA: The input channels feature internal optocouplers and resistor-capacitor isolation networks rated for up to 1500 V continuous isolation between field input terminals, ground, and the internal serial communication bus.\u003c\/p\u003e\n\u003cp\u003eQ: How does the IC660EBD110 handle 2-wire proximity switch field devices?\u003c\/p\u003e\n\u003cp\u003eA: The unit incorporates a 11.6 kohm input resistance delivering a preload current of 9.9 mA at 115 VAC, which provides sufficient resistive leakage current drain to ensure reliable activation and off-state threshold detection for standard 2-wire AC proximity switches.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eDisconnect all AC power sources feeding the IC660TBD110 terminal base and connected field devices before starting installation.\u003c\/li\u003e\n\u003cli\u003eVerify that the terminal base model is IC660TBD110 and that all terminal screws are properly secured.\u003c\/li\u003e\n\u003cli\u003eAlign the IC660EBD110 electronics assembly with the guide keys of the terminal base housing.\u003c\/li\u003e\n\u003cli\u003ePress the assembly firmly onto the terminal base mating connectors until the mechanical latch mechanism clicks securely into place.\u003c\/li\u003e\n\u003cli\u003eEnsure field input wiring utilizes recommended conductor gauges and that serial bus shield drain wires are tied to earth ground at a single node to suppress high-frequency noise.\u003c\/li\u003e\n\u003cli\u003eReapply main power to the assembly and observe the Unit OK LED indicator to confirm successful internal power-up diagnostics before placing the block online.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":45340499050611,"sku":"IC660EBD110","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/screenshot_2026-08-10_15-28-54_1200x1200_419637f1-7a95-4008-9af6-1cb1f5b7cadb.jpg?v=1786415582","url":"https:\/\/www.dcssupplier.com\/ar\/products\/ge-fanuc-ic660ebd110-genius-i-o-electronics-assembly","provider":"DcsSupplier Limited","version":"1.0","type":"link"}