{"product_id":"ge-fanuc-ic693chs392k-series-90-30-10-slot-expansion-baseplate","title":"GE Fanuc IC693CHS392K Series 90-30 10-Slot Expansion Baseplate","description":"\u003cp\u003eConfigured for rack expansion and remote module signal routing in Series 90-30 PLC systems, the \u003cstrong\u003eGE Fanuc IC693CHS392K\u003c\/strong\u003e (\u003cstrong\u003eIC693CHS392\u003c\/strong\u003e Expansion Baseplate) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eBase Model\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSuffix\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eIC693CHS392\u003c\/td\u003e\n\u003ctd\u003eK\u003c\/td\u003e\n\u003ctd\u003e10-Slot Expansion Baseplate Chassis, Revision K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC693CHS392K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.94 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e443 mm x 130 mm x 22 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e150 mA at 5 VDC (from backplane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Slots\u003c\/td\u003e\n\u003ctd\u003e10 I\/O and Option module slots (Slots 1 to 10)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCPU Slots\u003c\/td\u003e\n\u003ctd\u003eNone (Dedicated Expansion Baseplate)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply Slot\u003c\/td\u003e\n\u003ctd\u003e1 dedicated bay (leftmost position)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExpansion Interface\u003c\/td\u003e\n\u003ctd\u003e25-pin D-shell female connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Type\u003c\/td\u003e\n\u003ctd\u003ePanel mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum System CPU Support\u003c\/td\u003e\n\u003ctd\u003eUp to 7 expansion chassis connected per CPU system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity \u0026amp; I\/O Density Scaling\u003c\/h3\u003e\n\u003cp\u003eThe expansion baseplate is designed to maintain backplane bus communication velocity across multi-rack control topologies without introducing propagation delay. Interfacing directly via its integrated 25-pin D-shell female connector, the unit enables high-speed differential bus extension for deterministic data exchange with the primary CPU chassis. The layout provides high I\/O density scaling across 10 dedicated module slots, housing any mix of standard Series 90-30 discrete, analog, and option cards while powered by a local power supply module.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can a Series 90-30 CPU module be installed directly in the IC693CHS392K expansion baseplate?\u003c\/p\u003e\n\u003cp\u003eA: No. The IC693CHS392K contains no CPU slots and functions strictly as an expansion baseplate. The system CPU must reside in slot 1 of a primary CPU baseplate (such as IC693CHS397 or IC693CHS391).\u003c\/p\u003e\n\u003cp\u003eQ: What is the backplane current consumption requirement for this baseplate?\u003c\/p\u003e\n\u003cp\u003eA: The baseplate backplane logic circuitry draws 150 mA at 5 VDC from the system power supply installed in its dedicated power supply slot.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eMount the expansion baseplate securely to a clean metal panel within an indoor enclosure using grounded mounting screws.\u003c\/li\u003e\n\u003cli\u003eEnsure operating power is isolated from all system racks before connecting or disconnecting expansion cables to the 25-pin D-shell interface.\u003c\/li\u003e\n\u003cli\u003eInstall a compatible Series 90-30 power supply module into the leftmost dedicated power supply bay prior to powering the expansion rack.\u003c\/li\u003e\n\u003cli\u003eRoute expansion bus cabling in low-voltage raceways, maintaining separation from high-voltage AC conductors to preserve backplane noise immunity.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":45503489343603,"sku":"IC693CHS392K","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/IC693CHS397K2_Cocoai_5c4ef8bc-05aa-46cc-8ffe-d120952f90fd.jpg?v=1789530195","url":"https:\/\/www.dcssupplier.com\/ar\/products\/ge-fanuc-ic693chs392k-series-90-30-10-slot-expansion-baseplate","provider":"DcsSupplier Limited","version":"1.0","type":"link"}