{"product_id":"ge-fanuc-ic693cpu374-gp-series-90-30-plc-module","title":"GE Fanuc IC693CPU374-GP Series 90-30 PLC Module","description":"\u003cp\u003eThe \u003cstrong\u003eGE Fanuc IC693CPU374-GP\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIC693CPU374\u003c\/strong\u003e CPU Module, operates as a dedicated hardware component for high-speed logic execution and Ethernet communication management within Series 90-30 PLC backplane platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC693CPU374-GP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.36 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e130 mm x 40 mm x 140 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e7.4 W (from 5 VDC backplane bus)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor Speed\u003c\/td\u003e\n\u003ctd\u003e133 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUser Memory\u003c\/td\u003e\n\u003ctd\u003e240 KB configurable RAM \/ Flash memory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEmbedded Ports\u003c\/td\u003e\n\u003ctd\u003e2 Ethernet ports (RJ45, 10\/100 Mbit), 1 RS-485 serial port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDiscrete I\/O Capacity\u003c\/td\u003e\n\u003ctd\u003e4096 inputs, 4096 outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog I\/O Capacity\u003c\/td\u003e\n\u003ctd\u003e2048 input words, 512 output words\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity and Ethernet Integration\u003c\/h3\u003e\n\u003cp\u003eThe IC693CPU374-GP incorporates an integrated 133 MHz processor paired with a dedicated dual-port Ethernet interface, facilitating high-velocity backplane bus communication velocity across Series 90-30 expansion racks. Backplane data exchange latency is minimized via direct memory mapping, enabling deterministic update rates for high-density I\/O configurations. The module supports Ethernet communication protocols including SRTP and Modbus TCP\/IP. Firmware flash compatibility allows seamless updates over the Ethernet link or local serial connection, ensuring long-term maintainability without hardware extraction from the rack chassis.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What are the backplane power distribution constraints for the IC693CPU374-GP during hot-swapping or power-up?\u003c\/p\u003e\n\u003cp\u003eA: The IC693CPU374-GP draws up to 1.48 A at 5 VDC directly from the Series 90-30 baseplate bus. Hot-swapping of the CPU module is strictly prohibited; the baseplate power supply must be powered down prior to inserting or removing the unit to prevent backplane bus transients and firmware corruption.\u003c\/p\u003e\n\u003cp\u003eQ: How is memory retention managed during primary supply interruptions?\u003c\/p\u003e\n\u003cp\u003eA: RAM contents are maintained via a lithium battery connected to the CPU module baseplate circuit. Flash memory backup capability allows user applications and logic configurations to be permanently stored without continuous reliance on battery power.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003ePower Disconnection: Verify that all primary AC\/DC power sources to the baseplate and attached I\/O racks are fully de-energized prior to hardware insertion.\u003c\/li\u003e\n\u003cli\u003eBackplane Engagement: Align the IC693CPU374-GP module rear connectors with Slot 1 of the Series 90-30 baseplate. Press firmly until the top and bottom retention levers snap securely into place.\u003c\/li\u003e\n\u003cli\u003eCable Routing and Shielding: Ethernet cabling (Category 5e or higher STP) must be routed in separate wire trays from high-voltage AC power conductors. Ground the cable shield at the switch end to prevent ground loops.\u003c\/li\u003e\n\u003cli\u003eSerial Grounding: The 15-pin D-sub RS-485 serial port requires a dedicated drain wire connected directly to functional earth (FE) to maintain noise immunity in high-EMI environments.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":45473737343091,"sku":"IC693CPU374-GP","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/IC693CPU331X3_Cocoai.jpg?v=1789098870","url":"https:\/\/www.dcssupplier.com\/ar\/products\/ge-fanuc-ic693cpu374-gp-series-90-30-plc-module","provider":"DcsSupplier Limited","version":"1.0","type":"link"}