{"product_id":"ge-ic200alg620-bb-versamax-analog-input-module","title":"GE IC200ALG620-BB VersaMax Analog Input Module","description":"\u003cp\u003eConfigured for 4-point RTD and resistance input measurement in VersaMax I\/O backplane networks, the \u003cstrong\u003eGE IC200ALG620-BB\u003c\/strong\u003e (\u003cstrong\u003eIC200ALG620\u003c\/strong\u003e Analog Input Module) provides direct physical\/electrical execution. It handles signal acquisition for 3-wire and 4-wire resistance temperature detectors (RTDs) across 0-500 Ohms and 0-3000 Ohms ranges. Digitized signals pass to the central processing unit at 16-bit resolution over a 210 ms update cycle while maintaining high input-to-frame galvanic isolation.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eThe IC200ALG620 ordering string designates specific module revisions and manufacturing variants within the GE VersaMax series:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eIC200\u003c\/strong\u003e: VersaMax I\/O modular family architecture prefix.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eALG\u003c\/strong\u003e: Analog input hardware functional classification.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e620\u003c\/strong\u003e: 4-Channel RTD \/ Resistance input circuit design.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e-BB\u003c\/strong\u003e: Hardware revision index indicating specific firmware compatibility and upgraded internal component tolerances.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC200ALG620-BB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.18 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e110 x 60 x 67 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e125 mA at 5 VDC, 125 mA at 3.3 VDC (Backplane bus)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e4 points (RTD \/ Resistance)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e16 bits (15 bits plus sign)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUpdate Rate\u003c\/td\u003e\n\u003ctd\u003e210 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance Input Ranges\u003c\/td\u003e\n\u003ctd\u003e0-500 Ohms, 0-3000 Ohms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Wiring\u003c\/td\u003e\n\u003ctd\u003e3-wire and 4-wire RTDs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation (Input to Frame)\u003c\/td\u003e\n\u003ctd\u003e1500 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation (Input to Logic)\u003c\/td\u003e\n\u003ctd\u003e250 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy at 25 deg C\u003c\/td\u003e\n\u003ctd\u003e+\/-0.15 percent of full scale on resistance measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Sensitivity\u003c\/td\u003e\n\u003ctd\u003e+\/-0.004 percent of reading; +\/-1.5 uV per deg C referred to input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Lead Resistance\u003c\/td\u003e\n\u003ctd\u003e5 Ohms per lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Frequency\u003c\/td\u003e\n\u003ctd\u003e50-60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Interface \u0026amp; Network Determinism\u003c\/h3\u003e\n\u003cp\u003eThe module draws operating power directly through the VersaMax backplane bus interface, consuming up to 125 mA on the 5 VDC rail and 125 mA on the 3.3 VDC rail. It communicates deterministically across the backplane structure to maintain consistent channel sweep times. High-density I\/O routing utilizes channel-to-logic isolation limits rated at 250 VAC, preventing high-voltage noise spikes from degrading CPU backplane bus communication velocity and firmware execution stability.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the maximum allowable wire resistance for 3-wire and 4-wire RTD field connections?\u003c\/p\u003e\n\u003cp\u003eA: Maximum field lead resistance must not exceed 5 Ohms per lead. Exceeding this limit degrades the intrinsic lead-wire compensation accuracy on 3-wire RTD circuits.\u003c\/p\u003e\n\u003cp\u003eQ: Can this module operate without external field power?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The analog measurement circuits and digital processing logic derive operational current directly from the VersaMax backplane bus structure (125 mA maximum at 5 VDC and 125 mA maximum at 3.3 VDC).\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003ePower down the VersaMax I\/O rack backplane before inserting or removing the module from its carrier base to prevent transient arc faults.\u003c\/li\u003e\n\u003cli\u003eVerify that the carrier keying dials match the mechanical key configuration assigned to RTD input modules.\u003c\/li\u003e\n\u003cli\u003eKeep field lead length under recommended limits and use shielded twisted-pair cables for all 3-wire and 4-wire RTD sensors.\u003c\/li\u003e\n\u003cli\u003eTerminate overall cable shields to the nearest chassis ground bus bar or carrier frame ground terminal; do not float ground shields.\u003c\/li\u003e\n\u003cli\u003eEnsure field cable lead resistance remains equalized across all conductors of a channel circuit to maintain full temperature measurement accuracy.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":48395047796851,"sku":"IC200ALG620-BB","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/IC200ALG620-EB2_Cocoai_40f2b973-d706-49b3-9f87-574991b88132.jpg?v=1790062030","url":"https:\/\/www.dcssupplier.com\/ar\/products\/ge-ic200alg620-bb-versamax-analog-input-module","provider":"DcsSupplier Limited","version":"1.0","type":"link"}