{"product_id":"ge-ic200mdl750g-versamax-discrete-output-module","title":"GE IC200MDL750G VersaMax Discrete Output Module","description":"\u003cp\u003eThe \u003cstrong\u003eGE IC200MDL750G\u003c\/strong\u003e serves as the primary \u003cstrong\u003eIC200MDL750\u003c\/strong\u003e Discrete Output Module utilized to execute discrete output switching and load actuation across VersaMax platforms. It controls field-side DC loads across 32 positive logic sourcing channels organized into two isolated groups of 16 points each.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC200MDL750G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.69 lbs (0.31 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e110 mm x 66.8 mm x 50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 30 deg C (Without Derating)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e90 mA maximum backplane current\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Output Points\u003c\/td\u003e\n\u003ctd\u003e32 Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGroup Architecture\u003c\/td\u003e\n\u003ctd\u003e2 Groups of 16 Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003ePositive Logic (Sourcing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Voltage\u003c\/td\u003e\n\u003ctd\u003e12 \/ 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage Range\u003c\/td\u003e\n\u003ctd\u003e+10.2 to +30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Rating\u003c\/td\u003e\n\u003ctd\u003e0.5 A per point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush Current\u003c\/td\u003e\n\u003ctd\u003e2.0 A maximum for 100 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e0.2 ms ON \/ 1.0 ms OFF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Power Supply\u003c\/td\u003e\n\u003ctd\u003e10.2 to 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e250 VAC continuous; 1500 VAC for 1 minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eI\/O Density Scaling and Deterministic Response\u003c\/h3\u003e\n\u003cp\u003eThe high-density output module integrates 32 solid-state drivers within a single carrier footprint to maximize rack space efficiency. Internal logic registers update output channel states synchronously with backplane communication cycles to prevent switching latency. Integrated diagnostics monitor backplane supply levels and external field power status, illuminating front-panel status LEDs while maintaining deterministic execution across all output points.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How much backplane current does the module draw during operation?\u003c\/p\u003e\n\u003cp\u003eA: The unit draws a maximum of 90 mA from the 5 VDC VersaMax backplane bus. Field loads are powered entirely through external DC field power terminals.\u003c\/p\u003e\n\u003cp\u003eQ: What is the maximum permitted inrush current for inductive load switching?\u003c\/p\u003e\n\u003cp\u003eA: Each individual output channel supports a peak inrush current of up to 2.0 A for a maximum duration of 100 ms.\u003c\/p\u003e\n\u003cp\u003eQ: Does the module contain built-in internal fuses for output protection?\u003c\/p\u003e\n\u003cp\u003eA: No, the module does not contain internal user-replaceable fuses. External fusing or inductive load suppression circuits (such as flyback diodes) must be installed across inductive field loads to prevent channel damage.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eSnap the module securely onto its designated VersaMax I\/O carrier base mounted on a 35 mm DIN rail, verifying mechanical latches lock firmly in place.\u003c\/li\u003e\n\u003cli\u003eWire external 12\/24 VDC field power sources directly to the DC+ and DC- bus terminals on the carrier terminal block for both channel groups.\u003c\/li\u003e\n\u003cli\u003eInstall external inductive load suppression devices (such as flyback diodes) in parallel with relay coils or solenoid actuators to suppress transient switching voltage spikes.\u003c\/li\u003e\n\u003cli\u003eRoute field output conductors in separate wiring troughs away from high-voltage AC lines and sensitive analog signal cables to maintain noise immunity.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":45421963411571,"sku":"IC200MDL750G","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/IC200MDL750G_2_80fa01ed-1585-4385-bece-efb53275ce10.png?v=1788144257","url":"https:\/\/www.dcssupplier.com\/ar\/products\/ge-ic200mdl750g-versamax-discrete-output-module","provider":"DcsSupplier Limited","version":"1.0","type":"link"}