{"product_id":"ge-ic610chs130a-series-one-i-o-rack-1","title":"GE IC610CHS130A Series One I\/O Rack","description":"\u003cp\u003eThe \u003cstrong\u003eGE IC610CHS130A\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eIC610CHS130A\u003c\/strong\u003e Rack Module, operates as a dedicated hardware component for module housing and signal bus routing within GE Fanuc Series One PLC platforms. Featuring an integrated 115\/230 VAC power supply, this 10-slot metal chassis distributes internal operating power and establishes physical and electrical connections across installed CPU and I\/O modules.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC610CHS130A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.01 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e15.2 cm x 12.7 cm x 48.3 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eIntegrated 115\/230 VAC power supply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlot Capacity\u003c\/td\u003e\n\u003ctd\u003e10 slots\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Options\u003c\/td\u003e\n\u003ctd\u003ePanel mount or DIN rail mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChassis Material\u003c\/td\u003e\n\u003ctd\u003eIndustrial-grade metal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Method\u003c\/td\u003e\n\u003ctd\u003ePassive air ventilation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus Communication Velocity \u0026amp; Network Integrity\u003c\/h3\u003e\n\u003cp\u003eThe IC610CHS130A backplane bus maintains high-speed communication velocity, providing deterministic signal paths for address and data lines across all 10 slots. The integrated power supply unit regulates incoming 115\/230 VAC line power to supply continuous, ripple-free voltage to the internal bus logic. Firmware flash compatibility across connected CPU and expansion cards ensures synchronized I\/O scan execution, preventing bus lockups, parity errors, or signal interference across adjacent module slots.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Is live module insertion or hot-swapping supported on the IC610CHS130A rack?\u003c\/p\u003e\n\u003cp\u003eA: No, the main AC line power input to the rack must be de-energized before inserting or removing any CPU or I\/O module to prevent backplane arcing and bus corruption.\u003c\/p\u003e\n\u003cp\u003eQ: How is thermal heat dissipation managed within the IC610CHS130A enclosure?\u003c\/p\u003e\n\u003cp\u003eA: The chassis utilizes passive air ventilation through its slotted metal frame, requiring unimpeded convection airflow above and below the rack to maintain stable operating temperatures without external cooling fans.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eEnsure the primary 115\/230 VAC line power supply is fully isolated and de-energized prior to installing or servicing the rack assembly.\u003c\/li\u003e\n\u003cli\u003eMount the industrial metal chassis vertically onto a panel or DIN rail inside an enclosure, maintaining adequate vertical clearance for passive thermal ventilation.\u003c\/li\u003e\n\u003cli\u003eEstablish a direct low-impedance ground connection from the chassis ground lug to the local enclosure earth ground bus.\u003c\/li\u003e\n\u003cli\u003eAlign each Series One module with the card guides and insert firmly until the backplane edge connector fully seats into the chassis slot.\u003c\/li\u003e\n\u003cli\u003eVerify incoming AC input voltage selection (115 VAC or 230 VAC) matches facility power supply before energizing the system.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":48385058668659,"sku":"IC610CHS134A","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/IC610CHS130A_Cocoai.jpg?v=1789962737","url":"https:\/\/www.dcssupplier.com\/ar\/products\/ge-ic610chs130a-series-one-i-o-rack-1","provider":"DcsSupplier Limited","version":"1.0","type":"link"}