{"product_id":"ge-ic630mdl380-relay-output-module","title":"GE IC630MDL380 Relay Output Module","description":"\u003cp\u003eConfigured for discrete load switching in Series 90-30 PLC systems, the \u003cstrong\u003eGE IC630MDL380\u003c\/strong\u003e ( \u003cstrong\u003eIC630MDL380\u003c\/strong\u003e Relay Output Module) provides direct physical execution for field control circuits.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC630MDL380\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE (General Electric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eUSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.41 lbs (0.64 kg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard Series 90-30 single-slot module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e1.5 W backplane load (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Circuits\u003c\/td\u003e\n\u003ctd\u003e16 discrete outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContact Type\u003c\/td\u003e\n\u003ctd\u003eNormally Open (NO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Range\u003c\/td\u003e\n\u003ctd\u003e5 to 265 VAC \/ 5 to 265 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous Current\u003c\/td\u003e\n\u003ctd\u003e4 A continuous per circuit (subject to module derating)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eBackplane Bus \u0026amp; Deterministic Logic Execution\u003c\/h3\u003e\n\u003cp\u003eThe module operates over the backplane bus communication system, transferring discrete state bits between the CPU processor sweep and physical output relays. Deterministic logic updates ensure output coil activation aligns precisely with programmed task intervals. High I\/O density scaling allows 16 isolated logic circuits to reside within a compact single-slot chassis footprint, maintaining strict electrical isolation between low-voltage internal logic and external high-voltage field wiring.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can this relay output module be hot-swapped while the PLC rack is powered?\u003c\/p\u003e\n\u003cp\u003eA: No. Power to the rack backplane and external field circuit supply must be disconnected before inserting or removing the module to prevent electrical arcing and backplane logic corruption.\u003c\/p\u003e\n\u003cp\u003eQ: What is the maximum continuous current rating for a single output circuit?\u003c\/p\u003e\n\u003cp\u003eA: Each individual circuit supports a maximum continuous current of 4 A across the operating range of 5 to 265 VAC or 5 to 265 VDC. Overall module current capacity must adhere to system thermal derating guidelines.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eEnsure the PLC rack power supply is completely de-energized before mounting the module into the backplane slot.\u003c\/li\u003e\n\u003cli\u003eStrip field conductor insulation according to standard terminal block specifications, maintaining minimum 5 mm wire strip length.\u003c\/li\u003e\n\u003cli\u003eWire the field load circuits to the corresponding Normally Open terminal points, ensuring external surge suppression diodes or RC snubbers are installed across inductive loads.\u003c\/li\u003e\n\u003cli\u003eVerify field wiring insulation ratings exceed 300 VAC\/VDC to maintain compliance with channel isolation standards.\u003c\/li\u003e\n\u003cli\u003eTighten terminal block screws to the manufacturer recommended torque spec (0.5 to 0.6 Nm) and secure standard shield grounding at the enclosure entry point.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"GE","offers":[{"title":"Default Title","offer_id":45510604554355,"sku":"IC630MDL380","price":88.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0644\/4348\/2227\/files\/IC630MDL3802_96bfbb01-cc95-4c25-ac82-12dd74766d26.png?v=1789637805","url":"https:\/\/www.dcssupplier.com\/ar\/products\/ge-ic630mdl380-relay-output-module","provider":"DcsSupplier Limited","version":"1.0","type":"link"}